<p class="MsoNormal" style="text-align: justify;"><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry was earlier granted consent to operate under Water Act, 1974 vide no. CTOW/Renewal/LDH2/2020/13458784 dated 14/12/2020 expired on 30/06/2022 & under Air Act, 1981 vide no. CTOA/Renewal/LDH2/2020/13458781 dated 14/12/2020 expired on 30/06/2022.</span></p>
<p class="TableParagraph" style="text-align: justify;"><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-tab-count: 1;"> </span>Now, the industry has applied for renewal of consent to operate under the Water Act, 1974 & Air Act, 1981 through OCMMS.</span></p>
<p class="TableParagraph" style="margin-right: 4.65pt; text-align: justify; text-indent: .5in;"><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">It is intimated that the site of the industry was visited by AEE of this office on 15.11.2022 and it was observed that: -</span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry was in operation during the visit. </span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry has installed 1 No. Electric fired Hardening & Tempering furnace with adequate stack height. </span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry has installed induction furnace of capacity 300 kg/heat attached with bag filter house as per PSCST design as APCD. </span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry has already submitted the completion certificate from PSCST vide no. 1340 dated 04.08.2020. </span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry has installed one cupola furnace with wet scrubber as APCD and adequate stack height. The cupola furnace was lying in dismantled condition.</span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry has installed 3 No. shot blasting machines with bag house filter and adequate stack height. </span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry has installed two D.G sets of capacities 250 KVA & 125KVA, which are with canopy. </span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">Domestic effluent is being discharged onto land for plantation through septic tank.</span></p>
<p class="TableParagraph" style="text-indent: -.25in; mso-list: l0 level1 lfo1; tab-stops: 30.95pt; margin: .05pt 4.85pt .0001pt 23.45pt;"><!-- [if !supportLists]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">The industry is located in industrial zone as per Master Plan (2007-21), Ludhiana.</span></p>
<p class="TableParagraph" style="text-align: justify; text-indent: 24.7pt; margin: 0in 5.45pt .0001pt 4.5pt;"><span style="font-size: 10.0pt; color: black; mso-bidi-language: PA;">Keeping in view of the above, it is recommended that consent to operate under Water Act, 1974 may be granted upto 30.06.2026 with usual conditions. </span></p> |