| File Note: |
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">The project proponent was granted Consent to Operate under the Water (Prevention & Control of Pollution) Act, 1974 vide no. CTOW/Renewal/SAS/2021/16820274 dated 20.12.2021 and under Air (Prevention & Control of Pollution) Act, 1981 vide no. CTOA/Renewal/SAS/2021/16820264 dated 20.12.2021 for<span style="mso-spacerun: yes;"> </span>the manufacturing of the polyurethane water proofing coatings @ 2 KLD vide, which was valid upto 19.06.2022 with special conditions as under:</span></p>
<p class="MsoListParagraphCxSpFirst" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-IN">The industry will provide porthole and sampling platform with the stack.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-IN">The industry will obtain authorization under HWM Rules, 2016.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-IN">The industry will maintain record of generation and disposal of hazardous waste.</span></p>
<p class="MsoListParagraphCxSpLast" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">d)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-IN">The industry will get the stack emission monitoring and effluent monitoring of ETP during this period from NABL Laboratory and submit report.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">Now, the project proponent has applied for renewal of Consent to Operate under the Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 along with requisite documents.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">The project proponent has submitted CA Certificate with the value of fixed assets of Rs. 1.38 crore on 31.03.2022. Earlier, the industry has deposited Rs. 54,500/- vide UTR No. N245210737276063 dated 02.09.2021 under the Water (Prevention & Control of Pollution) Act, 1974 and Rs. 56,200/- vide UTR No. N245210737276427 dated 02.09.2021 under the Air (Prevention & Control of Pollution) Act. The consent fees submitted by the industry under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 is adequate up to 31.03.2029.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">The project proponent has submitted compliance report of the previous Consent to Operate under the Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 granted to it. </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">The project proponent has submitted analysis report of the stack emission and the sample collected on 12.11.2022 by M/s Industrial Testing Laboratory & Consulting House and the results are as under:</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><strong><span lang="EN-IN">Particulate Matter</span></strong><span lang="EN-IN"> – 129 mg/Nm3</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">The project proponent has submitted analysis report of the outlet of ETP and sample collected on 12.11.2022 by M/s Industrial Testing Laboratory & Consulting House and the results are as under:</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><strong><span lang="EN-IN">pH </span></strong><span lang="EN-IN">– 8.8, <strong>TSS</strong> – 17, <strong>TDS</strong> – 451, <strong>O & G</strong> -- <4.0, <strong>Phosphate</strong> – 1.5, <strong>Sulphate</strong> – 7.5</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">The results are within the prescribed limit of the Board. The lab is not NABL approved.</span></p>
<p class="MsoNormal" style="mso-margin-top-alt: auto; margin-bottom: 0in; text-align: justify; text-justify: inter-ideograph; text-indent: 1.0in; line-height: 13.8pt; background: white;"><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry was visited by under-signed on 23.11.2022 and contacted Sh. Jaswinder Singh, Quality Incharge (8289054902). During visit, it was observed as under:</span></p>
<p class="MsoListParagraphCxSpFirst" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">1)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry was not in operation. The industry is not being operated on a regular basis due to less demand for their product. The representative informed that the industry was last operated on 11.11.2022 and manufacturing of wall putty and tile adhesive powder was carried out.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">2)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry has installed ribben blending machine for blending raw material in powder form to make polyurethane waterproof coatings in powder form. The industry has provided a hood followed by a stack of adequate height with the blending machine. The industry has provided porthole and sampling platforms with the stack.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">3)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry has installed 3 no. vessels i.e. high speed dispenser of size 500 ltr , twin shift dispenser of size 1000 ltr and pre-polymer reactor of size 1000 ltr for blending of raw material in liquid form to make polyurethane water proof coatings in liquid form.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">4)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry has installed ETP of 1 KLD capacity for the treatment of wastewater. The ETP was not in operation at the time of the visit due to very less amount of water in the collection tank. The ETP comprises the collection tank, mixing tank followed by an activated carbon filter. The treated water after ETP is disposed off into sewer. The reading of energy meter was 2 kwh and reading of water meter at the outlet of ETP was 1.08 m3. The industry is maintaining the record of operation ETP. As per record ETP was last operated on 12.11.2022.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">5)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">Around 1.860 kgs of ETP sludge was lying stored in HDPE bag. The representative was advised to maintain record of generation and disposal of ETP sludge.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">6)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Verdana',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; color: #5d5d5d; background: white; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The reading of the water meter provided at the fresh water line in the process section from where water is used for washing purpose was 0000.32 m3. The industry is maintaining record of water consumption in washing.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">7)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Verdana',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; color: #5d5d5d; background: white; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry has not installed any DG set. </span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">8)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Verdana',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; color: #5d5d5d; background: white; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry has provided environmental data board outside the premises. </span></p>
<p class="MsoListParagraphCxSpLast" style="mso-margin-top-alt: auto; margin-bottom: 0in; margin-left: 22.5pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: normal; mso-list: l1 level1 lfo2; background: white;"><!-- [if !supportLists]--><span style="font-size: 13.5pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Tahoma; color: #5d5d5d; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;"><span style="mso-list: Ignore;">9)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 13.5pt; font-family: 'Verdana',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; color: #5d5d5d; background: white; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: PA;">The industry has provided dedicated hazardous waste room. </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN"> </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">In view of above, it is recommended that consent to operate under Water Act, 1974 and Air Act, 1981 may be renewed for short-term till 30.06.2023 subject to the following special conditions:</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">1) The industry will share time-schedule of operation of industry with the Board so that effluent sample monitoring and stack emission monitoring can be carried out by Board.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span lang="EN-IN">Competency: SEE</span></p> |