| File Note: |
<p class="MsoListParagraphCxSpFirst" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">A)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was granted consent to operate under Water (Prevention & Control of Pollution) Act, 1974 vide no. CTOW/Renewal/LDH3/2022/17669875 dated 18.02.2022, valid upto 17.02.2023 & under the Air (Prevention & Control of Pollution) Act, 1981 vide no. CTOA/Renewal/LDH3/2022/17669879 dated 24.01.2022 valid upto 30.06.2025 for production of knitted polyester cloth @ 300 Kgs/day & dyed polyester cloth on job basis @ 03 TPD for discharge of trade effluent @ 250 KLD onto land for plantation after treatment through ETP along with one boiler of capacity 03 TPH with twin cyclone followed by dual stage wet scrubber & one DG set of capacity 200 KVA equipped with canopy.<span style="color: red;"> </span></span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">B)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Thereafter, the industry was granted Consent to Establish/NOC expansion vide no. CTE/Exp/LDH3/2022/17665431 dated 22.03.2022 valid upto 19.01.2023 under the Water (Prevention & Control of Pollution) Act, 1974 & the Air (Prevention & Control of Pollution) Act, 1981 for production of Dyeing and Finishing of Polyester Fabric @ 25 Ton/Day or Dyeing and Finishing of Cotton/Polyester Cotton (Pc) @ 9.375 Ton/Day with discharge of trade effluent @ 250.0 KLD onto land for plantation after treatment in ETP & remaining 250 KLD into conveyance system of CETP 50 MLD and domestic effluent @2.0 KLD onto land for plantation after passing through septic tank & 0.8 KLD into the conveyance system to CETP 50 MLD located at Tajpur Road, Ludhiana along with two boilers of capacity @ 06 TPH & 03 TPH, 8 new soft flow machines and three DG sets of capacity 300 KVA, 200 KVA & 82 KVA with canopies each. </span></p>
<p class="MsoListParagraphCxSpMiddle" style="text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">C)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Now, the industry has applied for varied consent to operate under Water (Prevention & Control of Pollution) Act, 1974 & the Air (Prevention & Control of Pollution) Act, 1981 through OCMMS<span style="color: red;"> </span>for production of Dyeing and Finishing of Polyester Fabric @ 19.8 MTPD & Dyeing and Finishing of Cotton/Polyester Cotton (PC) @ 6.6 MTPD for discharge of trade effluent @ 431.2 KLD & domestic effluent @ 2.8 KLD into conveyance system of CETP 50 MLD alongwith one steam boiler of capacity @ 3 TPH & three DG sets of capacity 300 KVA, 200 KVA & 82.5 KVA equipped with canopies.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">D)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; color: red;"><span style="mso-spacerun: yes;"> </span></span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry had already deposited Rs. 86,400/- vide UTR No. SAA87907269 dated 05.08.2020 under Water Act, 1974 & Rs. 86,400/- vide UTR No. SAA87907150 dated 05.08.2020 under Air Act, 1981 which are adequate upto 31.08.2024 under both acts. </span></p>
<p class="MsoListParagraphCxSpLast" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">E)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was visited by the officer of this office on 15.11.2022 and observed that:-</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2; margin: 0in 0in .0001pt .5in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman';">The industry was in operation, during visit.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2; margin: 0in 0in .0001pt .5in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">2)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The industry has installed 5 soft flow of 450 Kg, 1 soft flow of 500 Kg and 4 soft flow of 300 Kg i.e. total 27 chambers of soft flow machines, Out of there 01 soft flow of 450 Kg & 01 soft flow 300 Kg were sealed by the team on 18.10.2022 & same was found sealed during visit. </span></p>
<p class="MsoListParagraphCxSpFirst" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The study on effluent generation has been done by the Guru Nanak Dev Engineering College (GNE) and as per report it has total effluent generation as 540 KLD from its total 27 chambers of soft flow machines. However, the industry has granted 434 KLD shares on 22.07.2022 of CETP, hence the discharge of the industry is 106 KLD more than the share allotted to it. Hence around 20% machinery of the industry was required to be sealed i.e. 01 soft flow of 450 Kg & 01 soft flow 300 Kg was sealed during visit on 18.10.2022 as per directions of the Competent Authority of the Board.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The industry is also installing 03 new soft flow machines (one of 450 kg & two of 300 kg each) at its site as per last NOC granted to it. However, there three soft flow machines are yet not commissioned and two machines were even without motors & connections.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The industry is connected with the conveyance system of CETP 50 MLD, Tajpur Road, Ludhiana for discharge its effluent. The industry has provided the flow meter at its final outlet leading to CETP. The industry was also advised to provide the flow meter at inlet water supply.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">6)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The industry has installed one </span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">steam </span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">boiler of capacity 0</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">3</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;"> TPH with cyclone as APCD in which rice husk was being used as fuel and adequate stack has been provided.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">7)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The stack emission samples collected by the Board on 30.12.2021 & as per analysis report the concentration of parameter is within the prescribed limits of the Board i.e. 200 mg/Nm<sup>3</sup>.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">8)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">The industry has also installed </span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">three</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;"> DG sets of capacity </span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">300</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;"> KVA</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">, 200 KVA & 82.5 KVA equipped with canopies</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;"> and adequate height</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">s</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">.</span></p>
<p class="MsoListParagraphCxSpLast" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">9)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;">Further, some units have made the complaint regarding in judicial allotment of the shares by the PDA, Tajpur Road, Ludhiana, which is under process at Board and at Govt. Level. </span></p>
<p class="MsoNormal" style="text-align: justify; line-height: 150%; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-weight: bold;"><span style="mso-tab-count: 2;"> </span>It is pertinent to mentioned here that the directions has been issued by the Board vide letter no. 6369-73 dated 17.10.2022 that no industry will install any new dyeing machinery without prior permission of the Board. In this case the industry had already obtained the NOC from the Board prior to above directions of the Board. However, the above said NOC was obtained by the industry for the discharge of </span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">trade effluent @ 250.0 KLD onto land for plantation after treatment in ETP & remaining 250 KLD into conveyance system of CETP 50 MLD, but present CTO has been applied for the discharge of trade effluent & domestic effluent @ 434 KLD into conveyance system of CETP 50 MLD.</span></p>
<p class="MsoBodyText2" style="text-align: justify; line-height: 150%; tab-stops: 9.0pt; margin: 0in 4.7pt 6.0pt 8.1pt;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 3;"> </span>Hence, till the finalization of the allotment of the shares of CETP 50 MLD, it is recommended that:</span></p>
<p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt .55in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman';">Consent to operate under the Air (Prevention & Control of Pollution) Act, 1981 may be considered for grant for one year with usual condition, please.</span></p>
<p class="MsoListParagraphCxSpLast" style="margin-left: .3in; mso-add-space: auto; text-align: justify; line-height: 150%;"><strong><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman';">Competency: SEE, ZO-II, Ludhiana</span></strong></p> |