<p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><u><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-style: italic;">Fume extraction system</span></u></strong></p>
<p class="MsoListParagraph" style="margin-left: .25in; mso-add-space: auto; text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style'; mso-ansi-language: EN-US; mso-bidi-font-style: italic;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span></strong><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;">There is no induction furnace in Mandi Gobindgarh and Khanna, who have installed fume extraction system to capture secondary emission. </span></p>
<p class="MsoNormal" style="margin-left: .25in; text-align: justify;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;">As directed by the Competent Authority of the Board, undersigned alongwith your goodself has visited PSCST, Chandigarh on 15.11.2022 and following discussion were done with Sh. Ranjit Singh and Sh. Pritpal Singh, PSCST. </span></p>
<p class="MsoListParagraphCxSpFirst" style="margin-left: 40.5pt; mso-add-space: auto; text-align: justify; text-indent: -22.5pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style'; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-style: italic;"><span style="mso-list: Ignore;">A.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span></strong><!--[endif]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-style: italic;">Primary Emission:</span></strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;"> Industries have installed fume extraction systems (FES) in form of side suction hoods and pulsejet bag filters (offline cleaning) with their induction furnaces having capacity 2 TPH to 30 TPH. These FES are capable of containing 100% of the primary emissions generated during the melting of raw material i.e. scrap. Around 1 kg to 3 kg dust per ton of scrap melting is being collected in pollution control device depending on the quality of the scrap. The performance of the FES depends on the raw material preparation and feeding practices as well as on the operation & maintenance of the air pollution control device. The SOPs regarding raw material and APCD are already being provided to the industry in the feasibility report as well as while issuing the completion certificate. Sometimes during the site visit, it has been observed that, industry is not filling the logbook of APCD genially. The Industry is always guided to Follow the SOPs during site visit. However, the problem of primary emissions would be there in case industry is not following SOPs sincerely.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: 40.5pt; mso-add-space: auto; text-align: justify; text-indent: -22.5pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style'; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-style: italic;"><span style="mso-list: Ignore;">B.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span></strong><!--[endif]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-style: italic;">Secondary emissions</span></strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;"> generate during taping of molten metal into the ladle and during transferring of the ladle to CM. The tapping time is 3-5 minutes per heat. Due to hot surface (1600°C) the dispersion of emissions in the shed area is fast and dispersion happens in all the directions of the atmosphere. Emissions from pouring/taping are usually uncontrolled. These emissions escape into the furnace shed and are vented through roof vents. The secondary emissions may be captured to some extent in an enclosed area either enclosing the plate form area or complete shed area. Dog house type hoods are used for covering the plate form area but this type of hood may not be installed in existing units due to space limitations. For enclosed shed area, a suction volume of around 2.5 to 3.5 lakh cubic meter is required for which an APCD will cost around 1.75 to 2.25 Cr. The cost of fabrication for enclosure of hood and civil work will be additional.</span></p>
<p class="MsoListParagraphCxSpLast" style="margin-left: 40.5pt; mso-add-space: auto; text-align: justify; text-indent: -22.5pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style'; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-style: italic;"><span style="mso-list: Ignore;">C.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span></strong><!--[endif]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-style: italic;">Fugitive emissions</span></strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;"> in the ambient area occur during various operations like raw material unloading, storage and transfer from scrap yard to platform area, cleaning of ingot molds with compressed air, slag grinding operations, casting shakeouts, vehicular movements etc. Thus the results of ambient air quality monitoring not only affected by primary or secondary emissions but fugitive emissions from various industrial inhouse operations shares significant part in ambient air pollution.</span></p>
<p class="MsoNormal" style="margin-left: .25in; text-align: justify;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Arial; mso-ansi-language: EN-US; mso-bidi-language: AR-SA; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;">Further, it was decided that Sh. Ranjit Singh, PSCST will visit 3-4 industries randomly alongwith officers of Regional Office, Fatehgarh Sahib and Air Lab, Head Office, Patiala to explore the possibility for secondary suction system.</span></p>
<p class="MsoListParagraphCxSpFirst" style="margin-left: .25in; mso-add-space: auto; text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style'; mso-ansi-language: EN-US; mso-bidi-font-style: italic;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span></strong><!--[endif]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-style: italic;">Recharge capacity of village pond to be adopted by the industry</span></strong><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;"> </span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;"> </span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span style="font-family: 'Bookman Old Style','serif';">As MC Mandi Gobindgarh has laid down sewerage network in Village Ajnali, therefore, the industry has decided to adopt village pond of Chattarpura for rain water harvesting. Accordingly, it has submitted NOC letter dated 29/09/2022 from Gram Panchayat, Chattarpura</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-weight: bold; mso-bidi-font-style: italic;"> </span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style'; mso-ansi-language: EN-US; mso-bidi-font-style: italic;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span></strong><!--[endif]--><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-style: italic;">Availability of green area to be developed etc.</span></strong></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Raavi; mso-ansi-language: EN-US; mso-bidi-font-style: italic;"> </span></strong></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span style="font-family: 'Bookman Old Style','serif';">Total area of the project is 21761.84 sqm.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span style="font-family: 'Bookman Old Style','serif';">Green belt required is 7184.01 Sqm.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span style="font-family: 'Bookman Old Style','serif';">However, the industry has planted saplings in 4 no. stretches having area 65 ft x 23 ft, 26 ft x 190 ft, 25 ft x 150 ft and 120 ft x 15 ft i.e. Green area developed is 1113.4429 sq.m., which comes out only 15 % of required green area.</span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span style="font-family: 'Bookman Old Style','serif';"> </span></p>
<p class="MsoListParagraphCxSpLast" style="margin-left: .25in; mso-add-space: auto; text-align: justify;"><span style="font-family: 'Bookman Old Style','serif';">Remaining land for development of green belt is available in industrial premises and it has assured to complete 33 % required green area by the next monsoon.</span></p> |