Show ApplicationProcessingDetails

Id: 20688617
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2022-12-20 14:33:40.77
File Note: <p class="MsoNormal" style="text-align: justify; text-indent: 25.2pt;"><span lang="EN-US">The industry was granted 'consent to operate' under the Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 on 31.03.2022 and 20.04.2022 respectively upto 31.12.2022, subject to the conditions mentioned therein along with special conditions as under:</span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall not discharge any trade effluent, cooling water, effluent from ash quenching or domestic effluent into any drain.</span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall install water meter on all the lines leading to different sections for supply of water to ascertain water consumption and waste water generation etc. within 01-month and maintain the records on daily basis. </span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall treat the entire effluents generating while cleaning of cooling towers, neutralization tanks etc. as well as domestic effluent in ETP installed &amp; operated by Sugar Mill in the premises. </span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall execute agreements for proper disposal of hazardous wastes of all categories with the concerned authorized companies and apply for authorization under Hazardous Wastes (Management, Handling &amp; Transboundary Movement) Rules, 2016 within 01-month. </span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall cover 100% fuel storage area by 31/05/2022.</span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall maintain arrangements to avoid flow of baggasse fuel ash in atmosphere by covering all transfer points of fuel conveying system properly &amp; sprinkling water etc.</span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall maintain &amp; operate the air pollution control device installed regularly &amp; efficiently all the times to achieve the prescribed parameters. </span></p> <p class="MsoListParagraph" style="margin-left: 25.2pt; text-align: justify; text-indent: -18.0pt; mso-list: l5 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall maintain the record of paddy straw procured / stored &amp; used as fuel and submit the same to the Punjab Pollution Control Board on monthly basis.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: 36.0pt;"><span lang="EN-US">To verify the above compliance, it is submitted that the industry was visited by the AEE on 28.06.2022 and it was observed that the industry was not complying with the consent conditions under Water Act, 1974 and Air Act, 1981. Accordingly, show cause notice for revocation of consent granted under the Water Act 1974, Air Act 1981 &amp; show cause notice for violation of provisions of Hazardous &amp; other Wastes Rules, 2016 was issued to industry with hearing before Chairman of the Board on 04/10/2022.</span></p> <p class="MsoNormalCxSpMiddle" style="text-align: justify;"><span lang="EN-US"><span style="mso-spacerun: yes;">&nbsp;</span><span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>After hearing, the officer of the Board and representative of the industry, the Chairman of the Board decided that:-</span></p> <p class="MsoNormalCxSpLast" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 1.0cm; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall submit the name of the bailers/rakers alongwith their contact numbers to whom the paddy is given by the industry within 15-days.</span></p> <p class="MsoNormal" style="margin-left: 1.0cm; mso-add-space: auto; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 1.0cm; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry shall remove all the shortcomings as observed during the visit on 28.6.22 and make 100% compliance before the commissioning of the unit in November 2022.</span></p> <p class="MsoNormal" style="margin-left: 1.0cm; mso-add-space: auto; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 1.0cm; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">Environmental Engineer Regional Office, Hoshiarpur shall visit the industry and submit the compliance alongwith recommendations in the matter within 2 months.<span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp; </span></span></p> <p class="MsoNormalCxSpFirst" style="text-align: justify;"><span lang="EN-US"><span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></p> <p class="MsoNormal" style="text-align: justify; text-indent: 7.2pt;"><span lang="EN-US">Now, the industry has applied for 'consent to operate' under the Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981.<span style="mso-spacerun: yes;">&nbsp; </span>The industry has submitted Authority letter, list of directors, , compliance report of consent conditions, CA Certificate. The industry has submitted the CA certificate for undepreciated cost of fixed assets of Rs. 93.50 crores. The industry has already deposited 'consent to operate' fee under both the Acts upto 31.03.2024. The penalty for late application @ 10% is deposited under both Act of Rs. 21,120/- vide receipt no. 000433193179 dated 13.12.2021, which is adequate.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: 7.2pt;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">Accordingly, the industry was visited by the undersigned on 19.12.2022 and contacted Sh. V.K. Chhajad, Site Incharge of the industry. The detail of the industry / visit is as under:</span></p> <p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US">General Information:</span></strong></p> <p class="MsoListParagraph" style="margin-left: 35.45pt; text-align: justify; text-indent: -32.4pt; mso-list: l2 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry is engaged in production of electricity through Co-generation power plant from biomass produced from Sugar Mill. During visit, the industry was under mechanical breakdown and was not in operation.</span></p> <p class="MsoNormal" style="margin-left: 35.45pt; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 35.45pt; text-align: justify; text-indent: -32.4pt; mso-list: l2 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry is generating power @ 15 MW from bio-mass @ 22 TPH. The bio-mass includes Bagasse, Parali, Fuel wood, Wood chips, Cane trash.</span></p> <p class="MsoNormal" style="margin-left: 35.45pt; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 35.45pt; text-align: justify; text-indent: -32.4pt; mso-list: l2 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-US" style="color: black; mso-themecolor: text1;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="color: black; mso-themecolor: text1;">The industry has submitted the bank guarantee of Rs. 3.0 lacs vide no. 166519IGPER0001 dated 15.10.2019 which has expired on 14.10.2020 and extended upto 14.10.2022 only. The industry has not renewed its said bank guarantee.</span></p> <p class="MsoListParagraph"><span lang="EN-US" style="color: black; mso-themecolor: text1;">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 35.45pt; text-align: justify; text-indent: -32.4pt; mso-list: l2 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-US" style="color: black; mso-themecolor: text1;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The manufacturing process is as under:</span></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="margin-left: 36.0pt; text-align: justify;"><span lang="EN-US">Soft Water (8%) + Power plant condensate (6.5%) + Steam condensate from sugar mill (85.5%) &ndash; De-aerator- Booster feed pump &ndash; HP heater &ndash; Economizer &ndash; Steam Drum &ndash; Saturated steam &ndash; Primary super heater &ndash; Secondary super heater &ndash; Turbine - Electricity. The exhaust steam from turbine is supplied to sugar mill process.<span style="mso-spacerun: yes;">&nbsp;&nbsp; </span></span></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US">Water Pollution and its Control:</span></strong></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -25.2pt; mso-list: l4 level1 lfo5;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry has installed a tubewell as source of fresh water. The digital water meter is installed with the tubewell and the reading of the same is noted as 330401 m3. </span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -25.2pt; mso-list: l4 level1 lfo5;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry has installed RO system having components: Multi grade filters, Quartz filter (membrane), RO system, De-gasifier (removal of O2), Mixed bed filter, Storage tank.<span style="mso-spacerun: yes;">&nbsp; </span></span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -25.2pt; mso-list: l4 level1 lfo5;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The softener plant is installed having components: Multi grade filter, Softener (addition of NaCL) &ndash; To cooling tower.</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -25.2pt; mso-list: l4 level1 lfo5;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">For regeneration of RO, the flushing with raw water is done and dosing of anti scaling agent (Antiscalant 9001 Thermax) is done. The wastewater is used for dust suppression and for wetting of ash.<span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp; </span></span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -25.2pt; mso-list: l4 level1 lfo5;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry drains about 3000 KL of wastewater from cooling tower once in season which shall be sent to the ETP of Sugar Mill for treatment. However, the treated effluent from the ETP of the Sugar Mill is being discharged into East Bein. The components of ETP installed in the Sugar Mill is: Grit screen, Equalization tank, Primary Clarifier, Secondary Clarifier &amp; Sludge drying beds.</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -25.2pt; mso-list: l4 level1 lfo5;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The housekeeping near the RO section and wet scrubber tanks was very poor.</span></p> <p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US">Air Pollution and its Control:</span></strong></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -28.4pt; mso-list: l7 level1 lfo6;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry has installed a boiler furnace which is travelling / moving grate type and is not FBC based.</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -28.4pt; mso-list: l7 level1 lfo6;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The boiler is producing steam @ 70 TPH and is using Bio-fuel @ 28 TPH to produce power @ 15 MWh.</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -28.4pt; mso-list: l7 level1 lfo6;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">ESP followed by a wet scrubber is installed as APCD.<span style="mso-spacerun: yes;">&nbsp; </span>A stack of about 60 m is provided with the APCD alongwith sampling arrangements. Separate energy meters are installed with the ESP and wet scrubber. As per record maintained by the industry, it is consuming about 450 KWh power with ESP and about 500 KWh with wet scrubber per day.</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -28.4pt; mso-list: l7 level1 lfo6;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">A lot of fly ash was found to be air-borne at the falling point of ESP hopper on conveyors, as the conveyors are not properly covered.</span></p> <p class="MsoListParagraph" style="margin-left: 21.3pt; text-align: justify; text-indent: -28.4pt; mso-list: l7 level1 lfo6;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">A regular complaint is being received from the residents of Nawanshahr city wrt air pollution and ash problem. It is pertinent to mention here that the industry has taken shut down on 13.12.2022 to check the problem and hired a consultant to rectify it. Now, the industry has submitted to DC ,SBS Nagar vide letter dt 16.12.2022 that the necessary amendments and repair of APCD has been done to mitigate the Air pollution problem.</span></p> <p class="MsoNormal" style="margin-left: 21.3pt; text-align: justify; text-indent: -28.4pt;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US">6.<span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>Bio-Mass Handling System:</span></strong></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 36.7pt; text-align: justify; text-indent: -25.8pt; mso-list: l6 level1 lfo7;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The bio-mass storage area is uncovered. The transfer points of bio-mass conveying system are not covered properly. Some of transfer points are covered with tarpuline sheet instead of providing a proper shed/ fixed enclosure.</span></p> <p class="MsoNormal" style="margin-left: -7.1pt; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 36.7pt; text-align: justify; text-indent: -25.8pt; mso-list: l6 level1 lfo7;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The bio-mass fuel charging area at the ground is full fugitive emissions. No hood system with suction facility / APCD is provided for collection / treatment of emissions being generated from bio-mass handling system.</span></p> <p class="MsoNormal" style="margin-left: -7.1pt; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 36.7pt; text-align: justify; text-indent: -25.8pt; mso-list: l6 level1 lfo7;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">All the floors under bio-fuel feeding point in the boiler furnace are covered with spillages of fuel which is becomes air-borne during wind flow and during its cleaning. The Slot Chain Area (Main feeding chain of bio-mass) is required to be modernize for proper feeding of bio-mass to the boiler furnace without spillages.</span></p> <p class="MsoNormal" style="margin-left: -7.1pt; text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US">7.<span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>Ash Handling System:</span></strong></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraphCxSpFirst" style="margin-left: 35.45pt; mso-add-space: auto; text-align: justify; text-indent: -1.0cm; mso-line-height-alt: 6.0pt; mso-list: l3 level1 lfo8;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">There are two no. of hoppers provided under the boiler furnace from where the ash is dumped over the conveyor belt which is filled with water to wet the ash. This ash is then filled into trollies for disposal of the same for land filling.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 35.45pt; mso-add-space: auto; text-align: justify; text-indent: -1.0cm; mso-line-height-alt: 6.0pt; mso-list: l3 level1 lfo8;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The ash heaps are required to be covered.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 35.45pt; mso-add-space: auto; text-align: justify; text-indent: -1.0cm; mso-line-height-alt: 6.0pt; mso-list: l3 level1 lfo8;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">Water sprinkler over ash handling area is installed which is operated manually as and when required.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 35.45pt; mso-add-space: auto; text-align: justify; text-indent: -1.0cm; mso-line-height-alt: 6.0pt; mso-list: l3 level1 lfo8;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The ash handling mechanism needs to be improved.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 35.45pt; mso-add-space: auto; text-align: justify; text-indent: -1.0cm; mso-line-height-alt: 6.0pt; mso-list: l3 level1 lfo8;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry has made agreement with M/s Chauhan Building Material for whole ash lifting.</span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: 0cm;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US"><span style="mso-spacerun: yes;">&nbsp;</span>8.<span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>Compliance of PH dt 4.10.2022:</span></strong></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: -18.0pt; mso-list: l1 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The record of paddy management wrt name of bailers / rakers has not been supplied .The transfer points of ash are not covered. Sprinkler system is provided over ash handling area. </span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: -18.0pt; mso-list: l1 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The wastewater drain existing in the fuel storage area is plugged. The cooling tower is full of water and representative of industry informed that this water shall be drained after 1-2 years. The ash quenching wastewater is recycled back to treatment facility. The domestic effluent disposal is not known to the unit and it is informed that the same is discharged into sugar mill system of wastewater.</span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: -18.0pt; mso-list: l1 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The representative of the industry informed that C.T. is not got empted in all reasons and is required to drain after about 3 years. </span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: -18.0pt; mso-list: l1 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry has made agreement with M/s Shiv Shanker Traders of Amritsar for category 33.1.</span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: -18.0pt; mso-list: l1 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The industry need to maintain proper and regular record of various activities w.r.t. consumption of various utilities generations. </span></p> <p class="MsoListParagraph" style="margin-left: 32.1pt; text-align: justify; text-indent: -18.0pt; mso-list: l1 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US">The record of hazardous waste is not maintained.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: 7.2pt;"><span lang="EN-US">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify;"><span lang="EN-US">The emission sample from the stack attached with the boiler was collected on30.11.2022 and as per analysis report, the PM in the emission is 38 mg/Nm3 @ 12% CO2, which is within permissible limits.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: 7.2pt;"><span lang="EN-US">In view of above, if approved, the ZO may be recommended that the application under the Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981<span style="mso-spacerun: yes;">&nbsp; </span>may be refused.</span></p> <p>(comp. Worthy Chairman)</p>
Inspection: false
Inspection Note:
Officer: PPCB126
Reject: false
Reject Note:
Role: RO AEE Sukhwant Singh