Show ApplicationProcessingDetails

Id: 20809123
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-01-05 14:13:30.214
File Note: <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">The project proponent was granted Consent to Operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 vide no CTOW/Fresh/SAS/2022/18995691 dated 22.08.2022, valid till 31.03.2023 and Air (Prevention &amp; Control of Pollution) Act, 1981 vide no. CTOA/Fresh/SAS/2022/18995863 dated 16.08.2022, valid till 31.12.2022 for manufacturing of Paracetamol @ 1000000 Numbers/Day, Livofloxacin @ 500000 Numbers/Day, Rabeprazole 350 @ 100000, Numbers/Day, Amoxy Clave @ 200000 Numbers/Day, Cephoparazone @ 100000, Numbers/Day, Sodium Citerate, Amonium &amp; Menthol Syrup @ 40000 no./day, Nimuslide @ 100000 no./day, Salbutamol Syrup @ 25000 no./day, Rantidyne Syrup @ 20000 no./day, Zental Albendazole Syrup @ 35000 bottle/day, Pentaprazole @ 120000 no./day, Ibuprofin @ 150000 no./day, Cefepime and Sulbactum @ 80000 no./day, Cefepime and Tazobactum @ 100000 no./day with special conditions as under:</p> <p class="MsoListParagraphCxSpFirst" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry will get the sample of trade effluent analysed from NABL approved lab and submit report to Board during this period.</p> <p class="MsoListParagraphCxSpLast" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry will get the stack emission analysis of boiler and 3 no. coating pans from NABL approved lab and submit report to Board during this period.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">Now, the project proponent has applied for renewal of Consent to Operate under the Air (Prevention &amp; Control of Pollution) Act, 1981 along with requisite documents.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">The project proponent has submitted CA Certificate with the value of fixed assets of Rs. 20.19 crore as on 30.06.2022. The project proponent has earlier deposited Rs. 36,000/- vide R. No. 231126406 dated 15.07.2022 under Air (Prevention &amp; Control of Pollution) Act, 1981, which was adequate for 31.01.2023.The project proponent has now deposited Rs. 36,000/- vide R No. <br />493770973 dated 03.01.2023 under Air (Prevention &amp; Control of Pollution) Act, 1981. Hence, the Consent to Operate fees is adequate till 30.09.2023 and Rs. 3200 is pending with Board.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">The project proponent has submitted compliance report of the previous Consent to Operate under the Air (Prevention &amp; Control of Pollution) Act, 1981 granted to it.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">The project proponent has submitted stack analysis report from NABL approved lab M/s Environ Tech Laboratories dated 31.12.2022 and the results are within permissible limits of the Board.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">The site was visited by the undersigned on 04.01.2023 and contacted Sh. Jagpreet Singh, Director (9878017896). During visit it was observed as under:</p> <p class="MsoListParagraphCxSpFirst" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry was in operation during visit and is manufacturing capsules, tablet and liquid syrup.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed 1 Ton CNG fired boiler at ground floor with stack of adequate height. The stack is provided with sampling platform.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed modular type ETP of 5 KLD capacity and has provided water meter at the inlet and outlet of ETP. The industry has provided sludge drying bed with the ETP. <span style="mso-spacerun: yes;">&nbsp;</span>The industry has provided softener after ETP so that the water can be used in boiler. The outlet of ETP was connected with the boiler feed and flushing line. The industry is maintaining record of operation of ETP and the reading of the same was 99 m3.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->1 no. DG set of capacity 200 KVA with canopy &amp; adequate stack height. The earlier installed 320 KVA &amp; 125 KVA DG set has been removed.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed manufacturing tanks for liquid syrups, 3 no. tablet coating pans, dry powder injection line, fluidized bed dryer, vacuum drying tray, blender etc. The industry has provided hood attached with common stack of adequate height with the 3 tablet coating pan. The industry has provided outlet of washing area of equipments into collection tank of the ETP. The blow down from chiller and boiler is also connected with ETP.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has provided laboratory at 2nd floor.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has provided 2 no. RO plant and DM plant. The partial permeate water from Ist RO is used as boiler feed &amp; use in process section for washing of utensils, partial amount of permeate water from Ist RO will be further treated in 2nd RO for use in manufacturing of batch of medicines. RO reject line is connected with ETP.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -23.25pt; mso-list: l2 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->Earlier, the industry was visited on 15.09.2022 and sample was collected from outlet of ETP and the results of the sample collected from outlet of ETP and are as under:</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; word-spacing: 0px;">pH -- 7.6, TSS -- 40&nbsp;, TDS &ndash; 374, COD &ndash; 72, BOD &ndash; 18, Phosphate -- 1.6, Ammonical, <span style="mso-spacerun: yes;">&nbsp;</span>Nitrogen -- 8.4, Phenolic Compound &ndash; BDL, Lead &ndash; BDL, Mercury &ndash; BDL, Arsenic &ndash; BDL, Total Chrome &ndash; BDL,</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; word-spacing: 0px;">Zinc &ndash; BDL, Copper &ndash; BDL, Cyanide &ndash; BDL, Sulphide &ndash; BDL, Oil &amp; Grease &ndash; BDL, Bio-Assay -- 90% survival of fish in 100% effluent after 96 hours.</p> <p class="MsoListParagraphCxSpLast" style="margin-left: 41.25pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; word-spacing: 0px;">The results are within the prescribed limit of the Board.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;">In view of above, it is recommended that &lsquo;consent to operate&rsquo; under the Air (Prevention &amp; Control of Pollution) Act, 1981 may be granted till 30.09.2023 with special conditions as under:</p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent will make agreement for disposal of ETP sludge with TSDF Nimbuan and will apply authorization under Hazardous &amp; Other Wastes (Management &amp; Trans boundary Movement) Rules, 2016 within 1 month.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><strong>*Competency &ndash; Chief Environmental Engineer </strong></p>
Inspection: false
Inspection Note:
Officer: PPCB114
Reject: false
Reject Note:
Role: RO AEE Piyush Jindal