| File Note: |
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">It is intimated that the industry is a small scale red category unit. </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol; color: black;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; color: black;">The industry was earlier granted consent to operate under Water (Prevention & Control of Pollution) Act, 1974 Vide No. CTOW/Varied/JAL/2018/8976948 dated 21.12.2018 valid upto 30.06.2022 and under Air (Prevention and Control of Pollution) Act, 1981 Vide No. CTOA/Fresh/JAL/2018/6177581 dated 08.01.2018 valid upto 30.06.2022 for manufacturing of Tablets and Capsules @20000Numbers/Day<span style="mso-spacerun: yes;"> </span>i.e Paracetamol @250Kg/Year, Amoxicillin @100Kg/Year, Starch @500Kg/Year, empty Capsuls @10000 Numbers/Day, Vitamins B1, B2 , B6 Etc @ 50 Kg/Year under red category. </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol; color: black;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; color: black;">Now, the industry has applied for Consent to Establish' (NOC for expansion) under Water (Prevention & Control of Pollution) Act 1974 & Air (Prevention & Control of Pollution) Act 1981 under red category through OCMMS of the Board for manufacturing of Paracetamol Tablets @ 10000000 Nmber/Year, Paracetamol Syrup @ 1000000 Nmber/Year, Aceclofenac tablets @ 1000000 Number/Year, Aceclofenac syrup @ 1000000<span style="mso-spacerun: yes;"> </span>Nmber/Year, Meropenem injection @ 500000 Number/Year, Cefexime tablets @ 9500000<span style="mso-spacerun: yes;"> </span>Number/Year,<span style="mso-spacerun: yes;"> </span>Cefexime dry syrup @ 500000 Number/Year, Amoxicillin capsules @ 2500000 Number/Year, Amoxicillin dry syrup @ 100000<span style="mso-spacerun: yes;"> </span>Number/Year, Telmisartan tablets @ 500000 Number/Year, Amlodipine tablets @<span style="mso-spacerun: yes;"> </span>500000<span style="mso-spacerun: yes;"> </span>Nmber/Year, Atorvastatin tablets @ 100000 Number/Year, Pregabalin capsules @ 500000 Nmber/Year, Nimesulide tablets @ 1000000<span style="mso-spacerun: yes;"> </span>Nmber/Year, Cefpodoxime tablets @ 500000<span style="mso-spacerun: yes;"> </span>Number/Year, Cefpodoxime dry syrup @ 500000 Number/Year, Ceftraxone injection @ 50000 Number/Year, Pipracillin tazobactum injection @<span style="mso-spacerun: yes;"> </span>Number/Year by using Paracetamol @ Tablets 1000 Kg/Year, Aceclofenac 1000 Kg/Year, Meropenem @ 500 Kgs/day, Cefexime @ 950 Kg/Year, Amoxicillin @ 350 Kg/Year, Telmisartan @ 100 Kg/Year, Amlodipine @ 100 Kg/Year, Atorvastatin @ 100 Kg/Year, Pregabalin @ 50 Kg/Year, Nimesulide @ 100 Kg/Year, Cefpodoxime @ 500 Kg/Year, Ceftraxone @ 50 Kg/Year, Pipracillin tazobactum @ 10 Kg/Year as raw material by proposed to install Effluent treatment Plant of capacity 5 KLD and 1 No. Auto Coater with water scrubber and DG set of capacity 363 KVA with canopy .</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol; color: black;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; color: black;">The industry has also applied for consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and under Air (Prevention and Control of Pollution) Act, 1981 online through OCMMS<span style="mso-spacerun: yes;"> </span>which is being processed separately.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was visited by officers of this office on 06.01.2023 and it was observed that the industry was in operation during visit and is engaged in manufacturing of</span><span lang="EN-US" style="font-family: 'Tahoma','sans-serif';"> </span><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">medicines (tables, capsules & syrups).</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has already started construction work at site for the proposed expansion project. The proposed expansion will be carried out within the existing premises and no new land will be acquired for the expansion. </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has proposed<span style="mso-spacerun: yes;"> </span>to install <span style="color: black;">1 No. Auto Coater for tables with water scrubber and adequate stack height.</span></span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol; color: black;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry has proposed<span style="mso-spacerun: yes;"> </span>to install <span style="color: black;">1 No. DG set of capacity 363 KVA with canopy and adequate stack height .</span></span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has proposed generation of trade effluent @ 3.0 KLD after the proposed expansion. The industry has proposed to install ETP of capacity 5 KLD for treatment of trade effluent. The feasibility report submitted for the same by the industry is principally adequate. </span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has proposed to utilize the treated effluent from ETP partly for flushing purpose and partly will be discharged for plantation purpose and remaining treated effluent <span style="mso-spacerun: yes;"> </span>left, if any, will be discharged into solar cum forced evaporation pond.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has proposed to discharge domestic effluent @ 2.0 KLD onto land for plantation after septic tank.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has already submitted area of classification certificate issued by DTP Jalandhar vide its memo no. 1635 dated 23.08.2017 and as per certificate the site of the industry falls in General Industrial Zone.</span></p>
<p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0cm 0cm .0001pt 18.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">·<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The proposed expansion project falls under red category small scale and the competency to decide such type of cases lies with Senior Environmental Engineer, Jalandhar.</span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 2;"> </span></span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';"> </span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 2;"> </span>Keeping In view of above, it is recommended that Consent to Establish (NOC) expansion under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 may be granted to the industry for one year with suitable conditions.</span></p> |