Show ApplicationProcessingDetails

Id: 20902323
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-01-17 13:22:01.17
File Note: <table class="MsoTableGrid" style="border-collapse: collapse; border: none; mso-border-alt: solid black .5pt; mso-border-themecolor: text1; mso-yfti-tbllook: 1184; mso-padding-alt: 0in 5.4pt 0in 5.4pt;" border="1" cellspacing="0" cellpadding="0"> <tbody> <tr style="mso-yfti-irow: 0; mso-yfti-firstrow: yes;"> <td style="width: 462.1pt; border: solid black 1.0pt; mso-border-themecolor: text1; mso-border-alt: solid black .5pt; padding: 0in 5.4pt 0in 5.4pt;" valign="top" width="616"> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Comments: It is intimated that the industry is small scale Wire drawing unit including acid pickling process and Sulphuric acid used in the process. It is verified from the purchase bill of sulphuric acid by the industry. Earlier, the industry was granted consent to operate under Water Act, 1974 vide No. CTOW/Fresh/LDH2/2018/8256539 dated 20.09.2018 which is valid upto 30.06.2022 for production of H.B. Wire @ 6 Ton per day including acid pickling process.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: normal;"><span lang="EN-IN" style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; color: black; mso-themecolor: text1;">The industry was visited by undersigned (JEE of this office) on 24.11.2022 and observed that :-</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry was in operation during the visit and was engaged in process of wire drawing including acid (Sulphuric) pickling process.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry has made an agreement with re-processor M/s JBR Technology Pvt. Ltd., Unit-II, Kohara, Ludhiana for lifting its spent acid generated from the acid pickling process @6000 litre per month.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry has installed 07 Drawing machines, 02 acid pickling tanks, 01 Lime tank and 01 washing tank.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry has installed water meter on its fresh supply of water leading to acid pickling process and its reading was 307.7 Kl during the visit and appx 6000 litre spent acid was in process.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry is maintaining the record of fresh water consumption viz-a-viz spent acid lifted by re-processor and found fresh water consumption , spent acid lifted to the re-processor and spent acid stored in the storage tank/processing tank was almost similar. </span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry is being discharged its domestic effluent into sewer.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry has not installed any boiler/furnace etc in its industrial premises.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry was granted consent to operate under Water Act, 1974 vide No. CTOW/Fresh/LDH2/2018/8256539 dated 20.09.2018 which is valid upto 30.06.2022 for acid pickling HCl) process. But the industry has made an agreement with JBR Technology Pvt. Ltd. Unit-II, at Kohara, Ludhiana and spent acid (Sulphuric acid) generated from the acid pickling process appx. @ 6000 litre per month lifted to the re-processor i.e. M/s JBR Technology Pvt. Ltd. Unit-II, at Kohara, Ludhiana.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">The industry is being operated without valid consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 and is violating various provisions of said acts.</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 115%; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">10.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-IN" style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">No bye pass has been observed during the visit.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Thereafter, the industry was issued show cause notice for violation under the provision of Water (Prevention &amp; Control of Pollution) Act, 1974 vide this office letter no. 1569 dated 16.12.2022 at Regional Office level with the request to submit reply in writing within 15 days to the reasons mentioned therein.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Now, the industry has applied for renewal of its existing consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 with requisite documents i.e. Compliance report of previous consent, latest CA certificate yearwise with total fixed assets for Rs. 69.17 lac, copy of Rent deed, detail of additional machinery and undertaking and copy of agreement with Re-processor i.e M/s JBR Technology Pvt. Ltd. Unit-II, Kohara for lifting of spent acid produced from acid pickling process @ 6000 litre/month. has submitted detail of additional machinery and certified that the industry has neither increased production capacity nor installed machinery which creates/increases pollution load. The industry has deposited for Rs. 44700/- vide UTR.No. N363222265281386 dated 29.12.2022 under Water Act, 1974<span style="mso-spacerun: yes;">&nbsp; </span>&amp;<span style="mso-spacerun: yes;">&nbsp; </span>Rs. 5400/- vide UTR No. N363222265281371<span style="mso-spacerun: yes;">&nbsp; </span>dated 29.12.2022 as NOC regularization fee on its increased fixed assets. Consent fee deposited by the industry is adequate upto 30.06.2027.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">During visit, water auditing was also carried out on 24.11.2022 and detail of the same is as under:-</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Opening balance of spent acid as on 01.05.2022 = 1300 litre</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Water meter reading was as per record maintained as on 01.05.2022= 258.70 Kl</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Water meter reading was on 24.11.2022 during the visit= 307.70Kl</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Total consumption during the period 49000 +1300=50300 litre and spent acid got lifted by re-processor 42000 litre and 6000 litre spent acid was in process tank.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry is complying with the conditions of previous consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 granted by the Board.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> </td> </tr> <tr style="mso-yfti-irow: 1; mso-yfti-lastrow: yes;"> <td style="width: 462.1pt; border: solid black 1.0pt; mso-border-themecolor: text1; border-top: none; mso-border-top-alt: solid black .5pt; mso-border-top-themecolor: text1; mso-border-alt: solid black .5pt; padding: 0in 5.4pt 0in 5.4pt;" valign="top" width="616"> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Recommendations:- Keeping in view of above, it is recommended that consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 may be granted upto 30.06.2027 to the industry as per policy of the Board with usual conditions. </span></p> <p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; line-height: 150%; margin: 0in 0in .0001pt .75in;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; line-height: 150%; margin: 0in 0in .0001pt .75in;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Submitted please.</span></p> <p class="MsoListParagraphCxSpLast" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> </td> </tr> </tbody> </table>
Inspection: false
Inspection Note:
Officer: PPCB118
Reject: false
Reject Note:
Role: RO JEE Malkit Singh