| File Note: |
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry is a small-scale orange category plyboard manufacturing unit and was visited by the officer of the Board on 29/12/2021 and found to be violating the provisions of the Air (Prevention & Control of Pollution) Act, 1981. The show cause notice was issued to the industry along with the opportunity for a personal hearing before Chief Environmental Engineer, Ludhiana wherein it was decided that Directions u/s 31-A of Air (Prevention & Control of Pollution) Act, 1981 may be issued for closure of the industry. Accordingly, the electricity connection was disconnected by PSPCL vide application no. 100018030108 dated 15-06-2022.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry later applied for fresh Consent to Operate under the Water Act, 1974 & Air Act, 1981 for Plywood & Board @ 600 Sq.m/day and was found complying. It was granted Consent to Operate accordingly which was valid upto 04/01/2023. The electricity connection of the industry was also restored temporarily for six months.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">Now, the industry has applied for renewal of Consent to Operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 along with requisite documents and fees.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry was visited by AEE on 08-12-2022 & observed as under:</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry was in operation during the visit and engaged in the manufacturing of plywood.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry has installed a wood-fired boiler of steam generation capacity 3TPH which has been equipped with cyclone as APCD and rotary valve has been provided with it.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The air emission samples were collected from the stack and as per Zonal Lab, Ludhiana letter no. 2166 dated 20/12/2022, the parameters are within the prescribed limits of the Board. (Particulate matter @ 218 mg/Nm3 against 500 mg/Nm3)</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry has not installed any glue kettles.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry has also installed one DG set of capacity 60 KVA equipped with a canopy and stack of adequate ht.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry has installed 16m stack height (AGL) with Boiler and 3m stack height with DG Set (AGL) and has installed Cyclone as APCD with Boiler. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">No untreated effluent through any illegal means was found during visit.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l1 level1 lfo1; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The domestic effluent is being discharged on to land for plantation after passing through the septic tank.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">In view of the above, it is recommended that:</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l0 level1 lfo2; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The industry may be granted consent to operate under Air (Prevention & Control of Pollution) Act, 1981 for 6 months.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -21.0pt; mso-list: l0 level1 lfo2; background: white; margin: 0in 0in 0in 22.5pt;"><!-- [if !supportLists]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: Arial; color: black;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">The PSPCL may be directed to restore electricity connection for further 6 months.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;"> </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-size: 11.0pt; font-family: 'Arial',sans-serif; color: black; background: white;">Competency – Chairman of the Board</span></p> |