Show ApplicationProcessingDetails

Id: 21069035
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-02-03 17:06:26.991
File Note: <p class="MsoPlainText" style="text-align: justify; text-justify: inter-ideograph; text-indent: 1.0in; line-height: 150%;"><span style="font-size: 11.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; font-style: normal;">The industry was issued show cause notice before refusal of 'consents to operate' under the Water Act, 1974 &amp; Air Act, 1981 with an opportunity of personal hearing on 17.10.2022 due to the following violations:-</span></p> <p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in 4.0pt 40.5pt;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif';">For the carbon powder generated from the reactor, underground room type storage provided, which is not completely closed and also no proper pneumatic/screw conveyor system provided to prevent the carbon powder emissions from the reactor into the atmosphere.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in 4.0pt 40.5pt;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif';">Wet scrubber provided as APCD with the furnace, but the same was not in working condition as there are openings in the APCD, with no provision for chemical dosing.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in 4.0pt 40.5pt;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif';">Sensor to measure the conc. of CO gas is not installed.</span></p> <p class="MsoListParagraphCxSpLast" style="mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in 4.0pt 40.5pt;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif';">The industry has not submitted the report from the concerned department related to adoption of safety measures inside its premises as prescribed by the Govt. of Punjab vide notification dated 15.10.2014.</span></p> <p class="MsoPlainText" style="text-align: justify; text-justify: inter-ideograph; text-indent: 1.0in; line-height: 150%;"><span style="font-size: 11.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; font-style: normal;">If approved, the Regional Office be requested to submit the compliance made by the industry w.r.t. observations earlier observed by the visting officer on 01.10.2022 to further process the application.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB075
Reject: false
Reject Note:
Role: ZO EE Ruby Sidhu