Show ApplicationProcessingDetails

Id: 21096676
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-02-07 16:04:36.893
File Note: <table class="MsoNormalTable" style="border-collapse: collapse; mso-table-layout-alt: fixed; mso-yfti-tbllook: 1184; mso-padding-alt: 0cm 0cm 0cm 0cm;" border="1" width="99%" cellspacing="0" cellpadding="0"> <tbody> <tr style="mso-yfti-irow: 3;"> <td style="width: 42.95pt; padding: 0cm 0cm 0cm 0cm;" width="57"> <table class="MsoNormalTable" style="border-collapse: collapse; mso-table-layout-alt: fixed; mso-yfti-tbllook: 1184; mso-padding-alt: 0cm 0cm 0cm 0cm;" border="1" width="99%" cellspacing="0" cellpadding="0"> <tbody> <tr style="mso-yfti-irow: 4;"> <td style="width: 42.95pt; padding: 0cm 0cm 0cm 0cm;" width="57"> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">It is intimated that the project proponent was granted Consent to Operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 vide no. CTOW/Renewal/SAS/2021/14590058 dated 19.01.2021 and Air (Prevention &amp; Control of Pollution) Act, 1981 vide no. CTOA/Renewal/SAS/2021/14589475 dated 19.01.2021, which is valid till 30.06.2024 for manufacturing of Silencer @ 3 MTD with certain conditions.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">Now, the project proponent has applied varied Consent to Operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 for manufacturing of Four head @ 200 MTD, Angle @ 200 MTD, Foot Plate @ 1500 MTD, Spice Plate @ 200 MTD, UHEAD @ 1500 MTD, Universal @ 200, Steel Waler @ 200 MTD, Bracing @ 1500 MTD &amp; Silencer @ 3 MTD along with requisite documents.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">The project proponent has submitted CA Certificate with value of fixed assets of Rs. 3.84 crore on 30.11.2022. Earlier, the industry has deposited Rs. 54,000/- vide no. UBINA20352710292 dated 17.12.2020 under the Water (Prevention &amp; Control of Pollution) Act, 1974 and Rs. 54,000/- vide no. UBINA20352711327 dated 17.12.2020 and Rs. 8200/- vide no. UBINA20352709876 dated 17.12.2020 under the Air (Prevention &amp; Control of Pollution) Act, 1981, which is valid upto 30.06.2024. Now, the project proponent has deposited Rs. 54000/- vide R no. 959267882 dated 03.02.2023 under Water Act, 1974 and Rs. 54000/- vide R no. 714516257 dated 03.02.2023 under Air Act, 1981.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">The project proponent has submitted transfer letter approved from PSIEC vide no. 11333 dated 04.08.1998 for manufacturing of Tractor parts in the name of M/s Jassi Forgings.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">On scrutinizing the application of the project proponent following observation were observed on 06.02.2023 with request to submit reply within 2 days.</p> <p class="MsoListParagraphCxSpFirst" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent has not submitted copy of agreement signed with Bantech Water Pvt. Ltd.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent has not submitted revised approved building plan from competent person under Factory Act, 1948.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent has not mentioned detail of water consumption, disposal in the process, in the application form.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent has not submitted compliance report of the previous Consent to Operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 granted to it.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent has not mentioned backing oven details in the application form.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent has not submitted analysis report of shot blast, powder coating booth &amp; baking oven from NABL approved lab.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent is required to submit proof of start of manufacturing of scaffolding, so that adequacy of the fees can be adjudged.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent is required to submit details of expansion made due to increase in fixed assets of Rs. 50 lakh to Rs. 3. 84 crore.</p> <p class="MsoListParagraphCxSpLast" style="margin-left: 70.9pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -21.25pt; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The project proponent not submitted manufacturing process details of scaffolding and any water pollution and Air pollution caused due to the process.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">No reply has been received from the project proponent.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; text-indent: 49.65pt;">The site was visited by the officer of the Board on 06.02.2023 and contacted Sh. Abhishek Sagar, Proprietor (9872246222). During visit it was observed as under:</p> <p class="MsoListParagraphCxSpFirst" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry is engaged in manufacturing of scaffolding &amp; silencers.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed 8 no. power press, 8 no. welding machine, break press, 3 tanks for phosphating, 1 no. Diesel fired baking oven in scaffolding section, 1 no. shot blasting in silencer section, 1 no. metalizing machine in silencer section, 2 no. electric oven, 1 no. powder coating oven and 1 no. diesel fired baking oven in silencer section.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed water meter on the line leading to phosphating process area and reading was 98146.97 KL.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has provided stack of adequate height but no sampling arrangement with 1 no. Diesel fired baking oven in scaffolding section, dust collector followed by stack of adequate height and sampling arrangement along with shot blast in silencer section, cyclone followed by stack of inadequate height &amp; sampling arrangement with the metalizing machine, multi cyclone followed stack of adequate height &amp; sampling arrangement with powder coating booth and stack of adequate height &amp; sampling arrangement with baking oven in silencer section.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry is carrying out dip painting of scaffolding and painting on silencer by pouring the liquid paint manually.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has made agreement with /s Bantech Water Pvt Ltd. for lifting of trade effluent @ 5000 ltr/ Month on 23.08.2022. The industry has installed 3 no. phosphating process and the trade effluent is also got lifted from these 3 tanks to Bantech.<span style="mso-spacerun: yes;">&nbsp; </span>The industry is maintaining the record of water consumption and wastewater generation. The industry has lifted trade effluent @ 3500 ltr vide manifest dated 20.12.2022 &amp; @ 3500 ltr vide manifest dated 11.01.2023. The wastewater lying in the tanks was matching with the record maintained by the industry.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed one no. DG set 125 KVA with canopy and adequate stack height.</p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has not made agreement with authorized recycler for disposal of empty paint containers. The industry has not obtained authorization under Hazardous &amp; Other Wastes (Management &amp; Trans boundary Movement) Rules, 2016.</p> <p class="MsoListParagraphCxSpLast" style="margin-left: 63.8pt; mso-add-space: auto; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry is located in industrial area approved for such type of industries and hence expansion can be allowed in this place.</p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span style="mso-spacerun: yes;">&nbsp;</span>In view of above, it is recommended that show cause notice for refusal of &lsquo;consent to operate&rsquo; under the Water (Prevention &amp; Control of Pollution) Act, 1974 and the Air (Prevention &amp; Control of Pollution) Act, 1981 with an opportunity of 15 days to submit reply in writing. <span style="mso-spacerun: yes;">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><strong>*Competency &ndash; Senior Environmental Engineer </strong></p> </td> </tr> </tbody> </table> </td> </tr> </tbody> </table>
Inspection: false
Inspection Note:
Officer: PPCB114
Reject: false
Reject Note:
Role: RO AEE Piyush Jindal