Show ApplicationProcessingDetails

Id: 21143344
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-02-13 13:41:11.808
File Note: <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: 1.0in; line-height: 150%;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry was granted &lsquo;Consent to Operate&rsquo; under the Water (Prevention &amp; Control of Pollution) Act, 1974 and the Air (Prevention &amp; Control of Pollution) Act, 1981 vide no. CTOW/Fresh/LDH3/2022/18869252 &amp; CTOA/Fresh/LDH3/2022/18847131 both dated 06.08.2022 for manufacturing of Telecom Terminals @ 13500 Nos/day, both valid upto 30.06.2023. </span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: 1.0in; line-height: 150%;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">Now, the industry has applied for obtaining renewal of &lsquo;Consent to Operate&rsquo; under the Water (Prevention &amp; Control of Pollution) Act, 1974 &amp; the Air (Prevention &amp; Control of Pollution) Act, 1981 through OCMMS. The industry has submitted that total gross block of fixed assets is Rs. 16.17 Crores. The industry has deposited Rs. 42,000/- vide UTR No. 233125953 dated 24.01.2023 under the Water Act, 1974 &amp; Rs. 42,000/- vide UTR No. 194313230 dated 24.01.2023 under the Air Act, 1981, which are adequate for period upto 31.12.2025 under both acts. </span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: 1.0in; line-height: 150%;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry was visited by AEE of this office on 13.02.2023 and it was observed as under:- </span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">1.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp;&nbsp; </span></span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The industry was in operation for manufacturing of telephone sets.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">2.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The industry is using ABS (polymer) as a raw material for making casing of telephone sets and other electronics/electrical components are used as raw material.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">3.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The machinery installed by the industry includes 15 no. injection molding machines, one SMT-line, Electricity oven, 02 no. auto insertion, 03 no. wave soldering.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">4.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The industry has installed wet scrubber as an APCD to control the emissions generated during soldering. The air emission samples were collected on 24.06.2022 and as per analysis report, concentration of SPM is 48 mg/ Nm<sup>3</sup>&nbsp;which is within the prescribed limits of the Board i.e. 150 mg/Nm<sup>3</sup>.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">5.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The industry has installed 03 no. DG sets, 02 of capacity 500 KVA &amp; 01 of capacity 125 KVA. The industry has placed in-acoustic enclosure room and also provided stacks of adequate height.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">6.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">There is no generation of trade effluent from process and only domestic effluent @ 20 KLD is generated.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">7.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The industry has installed STP for the treatment of domestic waste water generated from canteen/mess and staff/labor toilet. The effluent samples were collected from outlet to STP on 24.06.2022 and as per this analysis report concentration of various parameters is pH = 8.9, TSS = 45 mg/l, BOD = 06 mg/l and O&amp;G = BDL i.e. within the prescribed limits of the Board.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">8.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">Treated effluent from STP is discharged onto land for plantation. The industry has provided plantation all along the boundary wall and there is one lawn of size about 1.5 Kanal near STP. Total area available for discharge of treated water is about 3000 m<sup>2</sup>&nbsp;which is adequate for discharge of 20 KLD. The industry has provided proper distribution network for discharge of treated water into plantation area and in lawn. Condition of plantation is good.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">9.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The industry has submitted extended Bank Guarantee of Rs. 5.0 Lac bearing no. 0031NDDG00089423 dated 14.09.2022 valid for period upto 13.09.2023.</span></p> <p class="MsoNormal" style="text-align: justify; text-indent: -27.0pt; line-height: 150%; tab-stops: 27.0pt; background: white; margin: 0in 0in .0001pt .25in;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">10.</span><span style="font-size: 7.0pt; line-height: 150%; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;</span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">The competency to decide the case lies with the Senior Environmental Engineer, Ludhiana (Red/Small).</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: -.25in; line-height: 150%; background: white;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-language: PA;">Keeping in view of above, it is recommended that:</span></p> <p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in .0001pt 39.75pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-language: PA;"><span style="mso-list: Ignore;">A)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: 'Times New Roman'; background: white; mso-bidi-language: PA;">Renewal of &lsquo;Consent to operate&rsquo; under the Water (Prevention &amp; Control of Pollution) Act, 1974 for manufacturing of Telecom Terminals @ 13500 Nos/day may be granted to the industry for shorter period i.e. upto 30.06.2025 subject to suitable conditions.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB148
Reject: false
Reject Note:
Role: RO AEE Rajpal Gill