Show ApplicationProcessingDetails

Id: 21233849
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-02-23 12:50:31.689
File Note: <p class="MsoNormal" style="text-align: justify;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">It is intimated that the industry is a small scale tyre &amp; tube unit and was granted consents vide no. CTOW/Renewal/LDH2/2018/7133850 dated 27.3.2018 valid up to 31.03.2023 under Water Act, 1974 &amp; vide no. CTOA/Renewal/LDH2/2018/7132951 dated 27.03.2018 valid upto 31.03.2023 under Air Act, 1981 for the manufacturing of Bicycle Tyres @ 50010 pcs/day, Bicycle Tubes @ 60000 pcs/day, Automobile Tyres &amp; Tubes @ 3000 pcs/day.</span></p> <p class="MsoNormal" style="text-align: justify;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 2;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>Now, the industry has applied for renewal of consent to operate under the Water Act, 1974 &amp; the Air Act, 1981.<span style="mso-spacerun: yes;">&nbsp; </span>The industry has deposited Rs. 108000/- vide <span style="mso-spacerun: yes;">&nbsp;</span>online receipt no. 717349849 dated 21.2.2023 under Water Act, 1974 &amp; Rs. 108000/- vide online receipt no. 615830747<span style="mso-spacerun: yes;">&nbsp; </span>dated 21.2.2023 against the fixed assets of Rs. 998.23 Lacs, which is adequate upto 31.3.2028.</span></p> <p class="MsoNormal" style="text-align: justify;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>The site of industry was visited by the AEE of this office on 22.02.2023 and it was observed as under:-</span></p> <p class="MsoNormal" style="text-align: justify;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> <p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was in operation during visit. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed 2 no. rice husk fired boilers (one is standby) of 8 TPH capacity and trima cyclone is installed as APCD &amp; one more boiler of 4 TPH capacity and twin cyclone is installed as APCD alongwith adequate stacks with the boilers.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The air emission sample of 8 TPH boiler was collected by this office on 23.8.2022 and as per analysis report the SPM level was observed to be 188 mg/NM3 against the prescribed limit of 350 mg/NM3.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed mendling &amp; de-mendling section &amp; bag filter house installed as APCD. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed 3 no. D.G. set of capacity 400 KVA (2 no) each and 1 no. D.G. set 500 KVA capacity with canopies.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed STP for treatment of domestic effluent and after STP domestic effluent is discharged onto land for plantation &amp; cooling water is recirculated.<span style="mso-spacerun: yes;">&nbsp; </span>During the visit, no effluent was observed at the outlet of STP as it works on batch process and effluent was being collected in the collection tank. The component of the STP were in good operational condition.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Earlier, the effluent sample was collected by this office from final outlet of STP on 9.10.2019 and as per analysis report conc. of the parameters are pH = 7.6, TSS = 52 mg/l , TDS = 706 mg/l , COD = 156 mg/l , BOD = 48 mg/l , Oil &amp; Grease = 6.2 mg/l , as per analysis report, all the parameters are within the limits as prescribed by the Board for such discharges.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -22.5pt; line-height: 150%; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry is located in designated industrial zone i.e Industrial Area-C.</span></p> <p class="MsoListParagraphCxSpLast" style="mso-add-space: auto; text-align: justify; line-height: normal; margin: 0in 0in .0001pt 58.5pt;"><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;"><span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>Keeping in view of above, it is recommended that consent to operate under the Air Act, 1981 may be granted upto 30.6.2027<span style="color: red;"> </span>with usual conditions please. Competency SEE,<span style="mso-spacerun: yes;">&nbsp; </span>Z.O-1, Ludhiana.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB129
Reject: false
Reject Note:
Role: RO AEE Atul Kaushal