Show ApplicationProcessingDetails

Id: 21243887
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-02-24 12:43:41.107
File Note: <p style="text-align: justify;">The agenda note and report / recommendations of AEE/EE, RO, may kindly be perused.</p> <p style="text-align: justify;">It is submitted that the industry is medium scale red category unit. The industry was granted consent to operate under the Air Act, 1981, valid upto 31/03/2023 with certain conditions.</p> <p style="text-align: justify;">Now, the industry has applied for renewal of consent to operate under the Air Act, 1981. The industry has deposited consent fee, which is adequate upto&nbsp;31.03.2028.</p> <p style="text-align: justify;">To verify the facts, the industry was visited by officer of RO on 18.02.2023&nbsp;and it was observed as under:-</p> <p style="text-align: justify;"><!-- [if !supportLists]-->1.&nbsp;&nbsp;&nbsp; <!--[endif]-->The industry was in operation during the visit.</p> <p style="text-align: justify;"><!-- [if !supportLists]-->2.&nbsp;&nbsp;&nbsp; <!--[endif]-->The industry has installed 02 boilers of capacities 02 TPH &amp; 03 TPH and&nbsp;Pet coke is used as fuel.&nbsp;&nbsp;During visit boiler section was not in operation. The industry has installed multi cyclone followed by double stage alkali scrubber as APCD for both the boilers.&nbsp; The industry is maintaining the record of APCD operation.</p> <p style="text-align: justify;"><!-- [if !supportLists]-->3.&nbsp;&nbsp;&nbsp; <!--[endif]-->It is further informed that the stack emission sample of the industry&nbsp;has been collected on 10.08.22&nbsp;from porthole of 02 TPH of boiler stack after APCD and as per the analysis report, the SPM was found to be 165 mg/Nm3 against the prescribed limit of 500 mg/Nm3 and SO2=298 mg/Nm3 against the prescribed limit 400 mg/Nm3, which is within the prescribed limits of the Board.</p> <p style="text-align: justify;"><!-- [if !supportLists]-->4.&nbsp;&nbsp;&nbsp; <!--[endif]-->The industry has provided common stack with both boilers along with adequate arrangements for sample collection facilities.</p> <p style="text-align: justify;"><!-- [if !supportLists]-->5.&nbsp;&nbsp;&nbsp; <!--[endif]-->The representative of the industry informed that fuel ash generated from the burning of pet coke is being reused again.</p> <p style="text-align: justify;"><!-- [if !supportLists]-->6.&nbsp;&nbsp;&nbsp; <!--[endif]-->The industry has installed 02 D.G. sets of capacities 250 KVA &amp; 82 KVA with canopies and adequate stack heights.</p> <p style="text-align: justify;">In view of above, it is recommended that renewal of consent to operate under Air (Prevention &amp; Control of Pollution) Act, 1981 may be granted upto 30.06.2027&nbsp;with suitable conditions as per policy of the Board.</p> <p style="text-align: justify;">&nbsp;Competency : CEE, Ludhiana</p> <p style="text-align: justify;">&nbsp;</p>
Inspection: false
Inspection Note:
Officer: PPCB089
Reject: false
Reject Note:
Role: ZO EE Satyajit Attri