| File Note: |
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;"> </span>Kindly find attached the detailed inspection report along with agenda note. Further observations are as under:-</span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;"> </span>The project is a Gold Assaying and Hallmarking unit and has freshly applied for obtaining consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981. The unit has submitted latest CA certificate, Site Plan/Location Plan, Rent Deed, Manufacturing process, Plan showing the location of Scrubber/APCD, Agreement with TSDF at NIMBUA and request letter etc</span><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;">.</span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;"> </span>The unit was visited by officer of this office on 23/02/2023 and observed as under:-</span></p>
<p class="Default" style="margin-left: .5in; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 120%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: windowtext;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif'; color: windowtext;">The unit is a Gold Hallmarking center.</span></p>
<p class="Default" style="margin-left: .5in; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 120%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: windowtext;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif'; color: windowtext;">The unit has installed 01 no. small muffle furnace and 01 no. Hot Plate in an enclosure.</span></p>
<p class="Default" style="margin-left: .5in; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 120%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: windowtext;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif'; color: windowtext;">As per guidelines made by CPCB the unit has provided water scrubbing system with water circulation pump and same was attached with Hot Plate Chamber and muffle furnace. The system has provided to control fumes being generated/to be generated from cupellation process. </span></p>
<p class="Default" style="margin-left: .5in; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 120%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span style="font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: windowtext;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Tahoma','sans-serif'; color: windowtext;">The unit has installed a DG set of capacity 25 KVA, which is fitted with canopy.</span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;"> </span>It is further intimated that the unit falls in Orange category in the small-scale sector and competency to decide the case lies with Senior Environmental Engineer of the Board.</span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;"><span style="mso-tab-count: 1;"> </span>Keeping in view of above, it is recommended that t</span><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">he consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 may be granted to the unit up to 30/09/2023 <span style="mso-bidi-font-weight: bold;">with suitable terms & conditions along with special conditions as under:-</span></span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -0.25in; padding-left: 40px;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The unit shall submit the emission analysis report from Board's Lab within 02 months from the issuance of the consent.</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -0.25in; padding-left: 40px;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The unit shall not generate any effluent from its premises.</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -0.25in; padding-left: 40px;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The unit shall submit the Building plan approved by the competent person from the Deputy Director of Factories, Punjab.</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -0.25in; padding-left: 40px;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The unit shall apply for obtaining Authorization under HWM Rules, 2016 as per policy of the Board.</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -0.25in; padding-left: 40px;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The unit shall got lifted its hazardous waste of category 9.2 (Lead Ash) NIMBUA GREENFIELD PUNJAB LIMITED and shall submit the manifest in this office.</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -0.25in; padding-left: 40px;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The unit shall submit complete dimensional drawing along with adequacy certificate of the Wet scrubber installed in the premises.</span></p> |