<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%;"><span style="color: black; mso-bidi-language: PA;">The project proponent has applied for ‘Consent to Establish (NOC) from Pollution Angle under the provisions of Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 alongwith requisite documents for the establishment of new automobile workshop.</span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%;"><span style="color: black; mso-bidi-language: PA;"><span style="mso-tab-count: 1;"> </span>The project proponent has submitted project report with total cost of Rs. 498.27 Lacs and has deposited Rs. </span><span style="font-size: 12.0pt; line-height: 115%;">10,800</span><span style="color: black; mso-bidi-language: PA;">/- as NOC Fee on account of NOC fee which is adequate for one year. The industry has submitted CLU certificate issued vide no. 2679 dated 17.06.2022 stating that the site falls in Industrial mix zone as per Master Plan, Ludhiana (2007-21). The permission for CLU for commercial use is granted in view of instruction issued vide Punjab Government Notification No. CTP(SS)-2017/2200 dated 06.10.2017.</span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%;"><span style="color: black; mso-bidi-language: PA;"><span style="mso-tab-count: 1;"> </span>On perusal of the project report submitted by the industry, the project proponent has submitted following proposals :-</span></p>
<p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">The project proponent has proposed to establish a service station for washing of Maruti Suzuki vehicles </span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">As per the project report submitted, the project proponent has proposed to provide an effluent treatment plant of 15 KLD capacity consisting of pre-treatment (screening / Mud Trap, Oil skimmer, Equalization, Neutralization tank), secondary treatment (flash mixer, flocculator, tube settler) and tertiary treatment (sand and activated carbon filter) followed by disinfection done by ozonator/ UV/ Hypo-chloride. The project proponent proposes to reuse the effluent back in the process after treatment through the above automatic treatment plant. The feasibility report submitted by the project proponent is prinicipally adequate. <span style="mso-spacerun: yes;"> </span></span></p>
<p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">The domestic effluent generated from the project which shall be treated in an STP of capacity 20 KLD based on MBBR technology and shall be further reused for flushing purpose and remaining shall be discharged onto land for plantation and irrigation for which the project proponent has earmarked 1 Acre of land.</span></p>
<p class="MsoListParagraphCxSpLast" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">The hazardous waste of category 5.1,5.2, 21.1 and 34.3 shall be generated from the service station which shall be lifted to the authorized recycler.</span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; text-indent: 35.6pt; line-height: 115%;"><span style="mso-bidi-language: PA;">Accordingly, the site of the project was visited by the AEE of this office on 10.03.2023 and it was observed that :-</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l1 level1 lfo2; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">The project proponent has provided the boundary wall.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l1 level1 lfo2; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">The construction of the project has been started and the lanter work of the second floor is currently going on.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l1 level1 lfo2; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">No machinery has been installed yet.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: 115%; mso-pagination: widow-orphan; mso-list: l1 level1 lfo2; text-autospace: ideograph-numeric ideograph-other; margin: 0in 62.0pt .0001pt 74.7pt;"><!-- [if !supportLists]--><span style="mso-bidi-language: PA;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="mso-bidi-language: PA;">The project does not fall under the purview of EIA Notification, 2006 and also is not covered under SAC applicability under the Factories Act, 1948</span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%; mso-pagination: widow-orphan; text-autospace: ideograph-numeric ideograph-other;"><span style="mso-bidi-language: PA;"> </span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%; mso-pagination: widow-orphan; text-autospace: ideograph-numeric ideograph-other;"><span style="mso-bidi-language: PA;"> </span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%; mso-pagination: widow-orphan; text-autospace: ideograph-numeric ideograph-other;"><span style="mso-bidi-language: PA;"> </span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify; line-height: 115%;"><span style="color: black; mso-bidi-language: PA;">Keeping in view of above, it is recommended that :- </span></p>
<p class="MsoNormal" style="margin-right: 62.0pt; text-align: justify;"><span style="color: black; mso-bidi-language: PA;"> </span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -35.1pt; margin: 0in 62.0pt .0001pt 35.1pt;"><span style="color: black; mso-bidi-language: PA;">A<span style="mso-tab-count: 1;"> </span>The project proponent may be granted Consent to establish (NOC) under the provisions of the Water Act, 1974 & the Air Act, 1981 may be granted for one year with appropriate conditions and special conditions that :-</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -.25in; mso-list: l2 level1 lfo3; margin: 0in 62.0pt .0001pt .5in;"><!-- [if !supportLists]--><span style="color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="color: black; mso-bidi-language: PA;">The project proponent shall submit building plan approved by Director of Factories, Punjab before the commencement of operation.</span></p>
<p class="MsoListParagraph" style="text-align: justify; text-indent: -.25in; mso-list: l2 level1 lfo3; margin: 0in 62.0pt .0001pt .5in;"><!-- [if !supportLists]--><span style="color: black; mso-bidi-language: PA;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="color: black; mso-bidi-language: PA;">The project proponent shall comply with all the guidelines / conditions of CLU certificate issued vide no. 2679 dated 17.06.2022</span></p> |