Show ApplicationProcessingDetails

Id: 21384936
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-03-10 15:41:38.394
File Note: <p class="TableParagraph" style="margin-right: 5.05pt; text-align: justify; text-indent: 54.55pt; line-height: 150%;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%;">It is submitted that the industry was granted consent to operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 vide no. CTOW/Renewal/SGR/2022/19163647 dated 31/08/2022 &amp; the Air Act, 1981 vide no. CTOA/Renewal/SGR/2022/19164162 dated 31/08/2022, both valid upto 31/12/2022 to manufacture of Carbon black @ 25000 MT/Year by<span style="letter-spacing: -.25pt;"> </span>using Hydro Carbon Oil (Carbon Black Feed Stock) @ 210 MTD &amp; Light Diesel Oil. @ 0.4 MTD, as raw material with certain conditions mentioned therein and the electric connection of the industry was restored temporarily upto 31/12/2022.</span></p> <p class="TableParagraph" style="margin-right: 5.05pt; text-align: justify; text-indent: 54.55pt; line-height: 150%;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%;">Now, the industry has applied for renewal of consents to operate under the Water Act, 1974 &amp; the Air Act, 1981 through OCMMS of the Board.</span></p> <p class="TableParagraph" style="margin-right: 5.05pt; text-align: justify; text-indent: 54.55pt; line-height: 150%;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%;">The industry has deposited consents fee of Rs. 56000/-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; through online vide UTR No. AXISP00356353945 dated 21/01/2023 under the Water Act, 1974 &amp; Rs. 56000/- through online vide UTR No. AXISP00356353946&nbsp;&nbsp;&nbsp;&nbsp; dated&nbsp;&nbsp; 21/01/2023 under the Air Act, 1981, which is adequate upto adequate upto 30/09/2024, against the value of gross fixed assets of Rs. 1882.6559/- lacs dated 26/12/2022. </span></p> <p class="TableParagraph" style="margin-right: 5.45pt; text-align: justify; text-indent: 71.95pt; line-height: 106%;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">To verify the facts, the industry was visited by this office on 10/03/2023 and it was observed as under:-</span></p> <p class="TableParagraph" style="text-align: justify; line-height: 108%; margin: 0in 4.8pt .0001pt 0in;"><span style="font-size: 5.0pt; mso-bidi-font-size: 4.0pt; line-height: 108%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">&nbsp;</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 41.5pt; margin: 0in 5.0pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">1.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The industry as well as ETP &amp; APCD was in operation and the electric connection of the industry was found intact. The<span style="letter-spacing: -.1pt;"> </span>industry<span style="letter-spacing: -.15pt;"> </span>is maintaining<span style="letter-spacing: -.2pt;"> </span>the<span style="letter-spacing: -.15pt;"> </span>record<span style="letter-spacing: -.15pt;"> </span>regarding<span style="letter-spacing: -.2pt;"> </span>operation<span style="letter-spacing: -.1pt;"> </span>of<span style="letter-spacing: -.05pt;"> </span>ETP<span style="letter-spacing: -.1pt;"> </span>and<span style="letter-spacing: -.1pt;"> APCDs.</span></span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 41.5pt; margin: 0in 5.0pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">2.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The industry has installed 02 no. boilers each of capacity 12 TPH equipped with wet scrubber as APCD and common stack. The industry has dismantled the third boiler earlier installed by it.</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 106%; mso-list: l0 level1 lfo1; tab-stops: 38.4pt; margin: 0in 4.75pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">3.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%;">Th</span><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">e industry has made repair of the internal roads inside its premises with ready mix concrete.<span style="letter-spacing: -.1pt;"> The industry has failed to provide pavement near </span>the main gate of the industry<span style="letter-spacing: -.1pt;">.</span></span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 32.5pt; margin: 0in 4.7pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">4.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The industry is discharging its treated effluent onto land for plantation purposes. During visit, it was observed that the industry has provided new trees/sapling at place from where old trees are removed or died during the monsoon season in proper ridges and furrow in the plantation area. However, lot of wild grass was observed in the plantation area.</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 106%; mso-list: l0 level1 lfo1; tab-stops: 38.5pt; margin: 0in 4.9pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">5.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The<span style="letter-spacing: -.1pt;"> </span>samples<span style="letter-spacing: -.1pt;"> </span>of<span style="letter-spacing: -.15pt;"> </span>treated<span style="letter-spacing: -.2pt;"> </span>trade<span style="letter-spacing: -.1pt;"> </span>effluent<span style="letter-spacing: -.15pt;"> </span>and<span style="letter-spacing: -.05pt;"> </span>stack<span style="letter-spacing: -.2pt;"> </span>emissions<span style="letter-spacing: -.1pt;"> </span>were<span style="letter-spacing: -.1pt;"> </span>collected<span style="letter-spacing: -.15pt;"> </span>by<span style="letter-spacing: -.15pt;"> </span>this<span style="letter-spacing: -.15pt;"> </span>office<span style="letter-spacing: -.1pt;"> </span>on 14/07/2021 and analysis results are mentioned at B(ix) and E(i) respectively. The perusal of the said results reveals that the concentration of the various parameters is within the permissible limits as prescribed by the Board. The samples were not collected during the past year as the unit was not in operation during the visits.</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 106%; mso-list: l0 level1 lfo1; tab-stops: 35.2pt; margin: 0in 4.85pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">6.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 106%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The domestic effluent is being discharged onto land for plantation after passing through septic tank.</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 33.3pt; margin: 0in 4.95pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">7.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The industry has </span><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%;">installed the D.G. set of capacity 250 KVA equipped with canopy and stack of adequate height.</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 33.3pt; margin: 0in 4.95pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">8.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%;">No<span style="letter-spacing: -.2pt;"> </span>complaint<span style="letter-spacing: -.05pt;"> </span>is<span style="letter-spacing: -.05pt;"> </span>pending<span style="letter-spacing: -.25pt;"> </span>against<span style="letter-spacing: -.05pt;"> </span>the<span style="letter-spacing: -.05pt;"> </span>industry<span style="letter-spacing: -.3pt;"> </span>in<span style="letter-spacing: -.05pt;"> </span>the<span style="letter-spacing: -.1pt;"> </span>Regional<span style="letter-spacing: -.05pt;"> </span><span style="letter-spacing: -.1pt;">Office.</span></span><span style="font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';"> </span><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman';">The<span style="letter-spacing: -.1pt;"> </span>industry<span style="letter-spacing: -.15pt;"> </span>is maintaining<span style="letter-spacing: -.2pt;"> </span>the<span style="letter-spacing: -.15pt;"> </span>record<span style="letter-spacing: -.15pt;"> </span>regarding<span style="letter-spacing: -.2pt;"> </span>operation<span style="letter-spacing: -.1pt;"> </span>of<span style="letter-spacing: -.05pt;"> </span>ETP<span style="letter-spacing: -.1pt;"> </span>and<span style="letter-spacing: -.1pt;"> APCDs.</span></span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 33.3pt; margin: 0in 4.95pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">9.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-hansi-font-family: 'Times New Roman'; letter-spacing: -.1pt;">The </span><span style="font-size: 12.0pt; line-height: 107%;">industry was already submitted Bank Guarantee issued by M/s Shine Carbon and Chemical (P) Ltd. which was expired on 30/09/2022. The industry has been advised to submit the extended bank guarantee, immediately.</span></p> <p class="TableParagraph" style="text-align: justify; text-indent: -22.6pt; line-height: 107%; mso-list: l0 level1 lfo1; tab-stops: 33.3pt; margin: 0in 4.95pt .0001pt 27.9pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 107%; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: Cambria; letter-spacing: -.05pt;">10.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 107%;">The industry has failed to submit prior schedule for its operation in order to get its sample analyzed by the Board.</span></p> <p class="TableParagraph" style="text-align: justify; line-height: 107%; tab-stops: 7.25pt; margin: 0in 4.95pt .0001pt 2.75pt;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p> <p><span style="font-size: 11.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">In view of the above, it is therefore, recommended that renewal of consent to operate under the Water Act, 1974 &amp; the Air Act, 1981 may be refused after affording an opportunity of personal hearing before the Competent Authority of the Board due to above said violation, please.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB138
Reject: false
Reject Note:
Role: RO AEE Vipan Kumar