Show ApplicationProcessingDetails

Id: 21407601
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-03-13 16:04:16.281
File Note: <p class="MsoListParagraph" style="text-align: left; text-indent: -18.05pt; mso-list: l0 level1 lfo1; margin: 4.95pt 0cm .0001pt 35.45pt;" align="left"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt;">It<span style="letter-spacing: -.2pt;"> </span>is<span style="letter-spacing: -.1pt;"> </span>intimated<span style="letter-spacing: -.2pt;"> </span>that<span style="letter-spacing: -.1pt;"> </span>the<span style="letter-spacing: -.05pt;"> </span>industry<span style="letter-spacing: -.15pt;"> </span>is<span style="letter-spacing: -.1pt;"> </span>large<span style="letter-spacing: -.15pt;"> </span>scale<span style="letter-spacing: -.05pt;"> </span>red<span style="letter-spacing: -.2pt;"> </span>category<span style="letter-spacing: -.1pt;"> </span>unit.</span></p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l0 level1 lfo1; margin: 4.2pt 26.35pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%;">The industry was earlier granted consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention<span style="color: red;"> </span>&amp; Control of Pollution) Act, 1981 <span style="mso-spacerun: yes;">&nbsp;</span>Vide no. CTOW/Renewal/JAL1/2021/15743293 dated 01.12.2021 valid upto 31.03.2023 and vide no. CTOA/Renewal/JAL I/2021/15743759 dated 16.07.2021 valid upto 30.06.2023. </span></p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l0 level1 lfo1; margin: 4.2pt 26.35pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%;">Thereafter, the industry was granted consent to establish (NOC) under Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 vide no. CTE/Exp/JAL1/2022/18829982 dated 05.07.2022 valid upto 04.07.2023 for manufacturing of Dahi @ 50 MT/Day, Lassi @ 150 KL/Day, Kheer @ 1000 Kgs/day, Ghee @ 5 MT/Day, Panjiri @ 7 MT/Day, Milk Powder &amp; Dairy Whitener @ 25 MT/Day, Kaju Pinni @ 200 Kgs/day, Liquid Pouch Milk @ 240 KL/Day, Paneer @ 4 MT/Day and White Butter @ 8 MT/Day by using Rice @ 60 Kgs/day, Flour @ 3.5 Metric Tonnes/Day, Besan @ 1.5 Metric Tonnes/Day, Dry Fruits @ 15 Kgs/day, Sugar @ 7 Metric Tonnes/Day, Raw Milk @ 650 Metric Tonnes/Day as raw material by adding one new fermented product Plant of capacity 1.25 LLPD, a new Multi fuel Boiler of capacity 10 TPH and 1 No. DG set of capacity 750 KVA with canopy with total discharge of trade effluent @ 470 KLD and domestic effluent @ 25 KLD after treatment through ETP.</span></p> <p class="MsoListParagraph" style="line-height: 148%; mso-list: l0 level1 lfo1; margin: 3.95pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 148%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 148%;">Now the industry has applied for varied consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 for manufacturing of Liquid Pouch Milk @ 240 Kilo Liters/Day, Dahi @ 50 Metric Tonnes/Day, Lassi @ 150 Kilo Liters/Day, Kheer @ 1000 Kgs/day, Ghee @ 5 Metric Tonnes/Day Panjiri @ 7 Metric Tonnes/Day, Milk Powder &amp; Dairy Whitener @ 25 Metric Tonnes/Day, Kaju Pinni @ 200 Kgs/day, Paneer @ 4 Metric Tonnes/Day and White Butter @ 08 Metric Tonnes/Day by using Raw Milk @ 650 MT/Day Rice @ 60 Kgs/day, Sugar @ 7 MT/Day Flour @ 3.5 MT/Day Besan @ 1.5 MT/Day and Dry Fruits @ 15 Kgs/day as raw material. The industry has deposited Rs 7,20,000/- vide R no. 83409092 23.02.2023 under Water Act, 1974 and Rs 7,20,000/- vide R no. 101548554 13.03.2023 under Air Act, 1981, which is adequate upto 31.03.2026.</span></p> <p class="MsoListParagraph" style="line-height: 148%; mso-list: l0 level1 lfo1; margin: 3.95pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 148%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 148%;">The industry was visited by EE alongwith AEE on 09.03.2023 and it was observed<span style="letter-spacing: .05pt;"> </span>that the industry was in operation during visit and is engaged in manufacturing of<span style="letter-spacing: .05pt;"> </span>Dahi, Lassi, Kheer, Ghee, Panjiri, Milk Powder &amp; Dairy Whitener, Kaju Pinni, Liquid<span style="letter-spacing: .05pt;"> </span>Pouch<span style="letter-spacing: -.05pt;"> </span>Milk,<span style="letter-spacing: -.05pt;"> </span>Paneer,<span style="letter-spacing: -.1pt;"> </span>White Butter.</span></p> <p class="MsoListParagraph" style="line-height: 148%; mso-list: l0 level1 lfo1; margin: .5pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 148%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 148%;">The industry has installed 02 No. boiler of capacity 5 TPH and 1 No. coal fired boiler<span style="letter-spacing: .05pt;"> </span>of<span style="letter-spacing: 1.35pt;"> </span>capacity<span style="letter-spacing: 1.35pt;"> </span>3<span style="letter-spacing: 1.4pt;"> </span>TPH<span style="letter-spacing: 1.4pt;"> </span>with<span style="letter-spacing: 1.5pt;"> </span>Multi<span style="letter-spacing: 1.35pt;"> </span>Cyclone<span style="letter-spacing: 1.4pt;"> </span>Separator<span style="letter-spacing: 1.35pt;"> </span>followed<span style="letter-spacing: 1.4pt;"> </span>by<span style="letter-spacing: 1.45pt;"> </span>Bag<span style="letter-spacing: 1.45pt;"> </span>Filter<span style="letter-spacing: 1.4pt;"> </span>followed<span style="letter-spacing: 1.35pt;"> </span>by<span style="letter-spacing: -3.65pt;"> </span>wet<span style="letter-spacing: -.15pt;"> </span>scrubber.</span></p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; margin: .45pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 147%;">The industry has also installed 1 No. Thermic Fluid Heater of capacity </span>70000 Kcal/hous<span style="letter-spacing: -3.3pt;"> </span>with<span style="letter-spacing: -.05pt;"> </span>adequate stack<span style="letter-spacing: -.1pt;"> </span>height.</p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; margin: .45pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed 02 nos. DG sets of capacity 250 KVA and 750 KVA with canopies.</p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; margin: .45pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed one new fermented product Plant of capacity 1.25 LLPD.</p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; tab-stops: 51.55pt; margin: .2pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed Multifuel (coke/ rice husk/pet coke) Boiler of capacity 10 TPH with proposed APCD<span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 147%; letter-spacing: .05pt;"> </span>Multi<span style="letter-spacing: .05pt;"> </span>Cyclone<span style="letter-spacing: .05pt;"> </span>Separator,<span style="letter-spacing: .05pt;"> </span>Bag<span style="letter-spacing: .05pt;"> </span>Filter,<span style="letter-spacing: .05pt;"> </span>wet<span style="letter-spacing: .05pt;"> </span>scrubber. During, visit it was not in operation.</p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; margin: 7.15pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 147%;">The ETP was in operation &amp; treated effluent was being discharged into<span style="letter-spacing: .05pt;"> </span>sewer. The industry has provided online monitoring system. During visit, the readings were noted, pH-7.50, COD-66.2, TSS-23.9 and BOD- 10 mg/l.</span></p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; margin: 7.15pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 147%;">The effluent samples were collected during visit on 09.06.2022 by officers of this office and as per results, various parameters were found within the prescribed limit (pH-7.6, COD-80,BOD-23, TSS-18 and TDS- 670 and O&amp;G- 6.6)</span></p> <p class="MsoListParagraph" style="line-height: 147%; mso-list: l0 level1 lfo1; margin: 7.15pt 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 147%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 147%;">Further, the<span style="letter-spacing: .95pt;"> </span>effluent<span style="letter-spacing: .9pt;"> </span>samples<span style="letter-spacing: 1.05pt;"> </span>were collected<span style="letter-spacing: .85pt;"> during the visit on </span>23.11.2022<span style="letter-spacing: 1.05pt;"> </span>and<span style="letter-spacing: .85pt;"> </span>sent<span style="letter-spacing: -3.6pt;"> </span>to<span style="letter-spacing: -.15pt;"> </span>PBTI Lab, Mohali for analysis.<span style="letter-spacing: .05pt;"> </span>As per analysis report received from PBTI, Mohali, all the parameters are found within the prescribed limits of the Board (pH-8.68, COD-9,BOD-&lt;1, TSS-1.1, TDS- 996, O&amp;G- BDL and MLSS- 4111)</span></p> <p class="MsoListParagraph" style="line-height: 148%; mso-list: l0 level1 lfo1; margin: 0cm 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 148%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 148%;">The stack emission samples from boiler of capacity 05 TPH were collected on 09.06.2022. As per analysis report the particulate matter is 12 mg/Nm3 at 12% CO<sub>2</sub> which is within the limit prescribed by the Board.</span></p> <p class="MsoListParagraph" style="line-height: 148%; mso-list: l0 level1 lfo1; margin: 0cm 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 148%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 148%;">The industry has already installed the CCTV cameras covering various components of effluent treatment plant.</span></p> <p class="MsoListParagraph" style="line-height: 148%; mso-list: l0 level1 lfo1; margin: 0cm 24.85pt .0001pt 35.45pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 148%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 148%;">Th<span style="letter-spacing: .85pt;">e </span>industr<span style="letter-spacing: .8pt;">y </span>i<span style="letter-spacing: .9pt;">s </span><span style="letter-spacing: .75pt;">a </span>larg<span style="letter-spacing: .9pt;">e </span>scal<span style="letter-spacing: .9pt;">e </span>re<span style="letter-spacing: .75pt;">d </span>categor<span style="letter-spacing: .95pt;">y </span>an<span style="letter-spacing: .85pt;">d </span>th<span style="letter-spacing: .85pt;">e </span>competenc<span style="letter-spacing: .85pt;">y </span>t<span style="letter-spacing: .9pt;">o </span>decid<span style="letter-spacing: .85pt;">e </span>suc<span style="letter-spacing: 1.0pt;">h </span>type <span style="letter-spacing: -3.6pt;"><span style="mso-spacerun: yes;">&nbsp;</span><span style="mso-spacerun: yes;">&nbsp;</span></span>o<span style="letter-spacing: -.1pt;">f </span>cases lies wit<span style="letter-spacing: -.05pt;">h </span>Hon&rsquo;ble Chairma<span style="letter-spacing: -.05pt;">n </span>o<span style="letter-spacing: .05pt;">f </span>the Board.</span></p> <p class="MsoBodyText" style="text-indent: 0cm; line-height: 150%; margin: 3.9pt 0cm .0001pt 19.6pt;"><span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp; </span>In<span style="letter-spacing: -.15pt;"> </span>view<span style="letter-spacing: -.15pt;"> </span>of<span style="letter-spacing: -.1pt;"> </span>above,<span style="letter-spacing: -.1pt;"> </span>it<span style="letter-spacing: -.2pt;"> </span>is recommended that varied consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 may be granted to the industry upto 31.03.2026 with usual conditions as per policy of the Board please.</p>
Inspection: false
Inspection Note:
Officer: PPCB076
Reject: false
Reject Note:
Role: RO AEE Sandeep Kaur