Show ApplicationProcessingDetails

Id: 21414336
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-03-14 11:19:54.252
File Note: <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph;"><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;">The point wise reply to the observations is as under:-</span></p> <p class="MsoListParagraphCxSpFirst" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;">The industry has installed Multifuel (coke/ rice husk/pet coke) Boiler of capacity 10 TPH with APCD Multi Cyclone Separator, Bag Filter, wet scrubber alongwith adequate stack height. During visit, it was not in operation.</span></p> <p class="MsoListParagraphCxSpMiddle" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;">The industry has installed 02 nos. boilers of capacity 05 TPH and one boiler of capacity 03 TPH. All the boilers are provided with common stack height.</span></p> <p class="MsoListParagraphCxSpMiddle" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;">The industry has installed ETP comprising of following components:- Collection tank </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> Neutralization tank </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> DAF </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> Extended Aeration </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> Clarifier </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> PSF </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> ASF </span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; font-family: Wingdings; mso-ascii-font-family: Calibri; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Calibri; mso-hansi-theme-font: minor-latin; mso-char-type: symbol; mso-symbol-font-family: Wingdings;"><span style="mso-char-type: symbol; mso-symbol-font-family: Wingdings;">&agrave;</span></span><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;"> Into sewer.</span></p> <p class="MsoListParagraphCxSpLast" style="text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 13.0pt; mso-bidi-font-size: 11.0pt; line-height: 115%;">The industry is discharging its effluent into sewer after treatment through ETP.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB076
Reject: false
Reject Note:
Role: RO AEE Sandeep Kaur