Show ApplicationProcessingDetails

Id: 21435311
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-03-15 12:38:03.281
File Note: <p class="MsoListParagraphCxSpFirst" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">A)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was granted consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 vide no. CTOW/Varied/LDH3/2022/19550064 dated 26.10.2022, which valid upto 25.01.2023 <span style="mso-bidi-font-weight: bold;">for production of Dyeing of P.C. Cloth @ 2000 Kgs/day, Washing of Garments @ 300 Numbers/Day with discharge of trade effluent @ 99.5 KLD &amp; domestic effluent @ 0.5 KLD with conditions mentioned therein. </span></span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">B)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">Thereafter, the industry had applied for renewal of consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 through OCMMS, which was refused vide no. CTOW/Renewal/LDH3/2023/20953501 dated 28.02.2023 due to the industry was operating its all machinery and no seal was found intact on its earlier sealed machine.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">C)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">Accordingly, the Competent Authority of the Board has issued directions u/s 33-A of the Water (Prevention &amp; Control of Pollution) Act, 1974 to PSPCL authorities to disconnect the electric supply of the industry. The PSPCL authorities vide TDCO no. 115/298 dated 07.03.2023 has disconnect the electric supply of the industry.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">D)<span style="font: 7.0pt 'Times New Roman';">&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">Now, the industry has applied for renewal of consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 for dyeing of PC Clothes @ 2000 kgs/day, washing of garments @ 300 nos/day and discharge of trade effluent @ 99.5 KLD &amp; domestic effluent @ 0.5 KLD into CETP 50 MLD conveyance system. The industry has submitted request to restore the electric supply of the industry. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">E)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The industry has already deposited Rs. 4040/- (2940/- water + 1100 NOC) </span><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">vide UTR No. SDL111140215 dated 18.08.2022 under Water Act, 1974, which is adequate upto 30.06.2027.</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">F)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was visited by AEE of this office on 11.03.2023 and it was observed as under:-</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-left: 58.5pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was not in operation during the visit and its electric connection was found disconnected.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt 10.0pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed 4 soft flow dyeing machines of capacities 450 kg X2 &amp; 250 kg X 2 for dyeing of polyester fabric having total 10 chambers &amp; one sample machine. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt 10.0pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The study on effluent generation has been done by the Guru Nanak Dev Engineering College (GNE) and as per report it has total effluent generation as 240 KLD from its total 12 chambers. However, the industry has granted 100 KLD shares of CETP, hence due to excess discharge one soft flow of 450 Kgs and one soft flow of 250 Kgs was sealed by the Board. Thereafter, the industry has removed the 01 sealed soft flow machine of capacity 250 from its premises and present only have 10 chambers. Hence, as per GNE calculation the effluent generation will be 200 KLD. The industry had removed the seal from its machine at its own. Therefore, one soft flow of 450 Kgs and 01 soft flow of 250 Kgs i.e. total 05 chambers is required to be seal.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The industry has submitted the detail of nos of lots, nos of bath, liquor ratio, production and corresponding effluent generation and same is enclosed in the list of the documents submitted by the industry and matching with the data given in the application form.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The industry is connected with the conveyance system of CETP 50 MLD, Tajpur Road, Ludhiana for discharge its trade &amp; domestic effluent. The industry has provided the flow meter at its final outlet leading to CETP. The industry was also advised to provide the flow meter at inlet water supply. </span></p> <p class="MsoListParagraphCxSpLast" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;">The industry has provided the arrangement to re used its cooling water and steam condensate.</span></p> <p class="MsoBodyText2" style="text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; font-weight: normal; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; font-weight: normal; mso-bidi-font-weight: bold;">Further, some units have made the complaint regarding in judicial allotment of the shares by the PDA, Tajpur Road, Ludhiana, which is under process at Board and at Govt. Level.</span></p> <p class="MsoBodyText2" style="text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; font-weight: normal; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; font-weight: normal; mso-bidi-font-weight: bold;">The industry is using solid wood pieces as fuel in its furnace and also provided mechanical feeder for agriculture fuel.</span></p> <p class="MsoBodyText2" style="text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2; tab-stops: 512.6pt; margin: 0in 4.7pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; font-weight: normal; mso-bidi-font-weight: bold;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; font-weight: normal; mso-bidi-font-weight: bold;">The water scrubber is provided by the industry and its piping work is also completed.</span></p> <p class="MsoListParagraphCxSpFirst" style="text-align: justify; line-height: 150%;"><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: 6.0pt; mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">G)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">In view of above, it is recommended that:</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3; margin: 0in 0in 6.0pt 1.05in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Consent to operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 be granted to the industry for six months with usual conditions.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3; margin: 0in 0in 6.0pt 1.05in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Directions u/s 33-A of the Water (Prevention &amp; Control of Pollution) Act, 1974 be issued to the PSPCL authorities to temporarily restoration of electric supply of the industry for six month, please.</span></p> <p class="MsoListParagraphCxSpLast" style="mso-add-space: auto; text-align: justify; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3; margin: 0in 0in 6.0pt 1.05in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Directions u/s 33-A of the Water (Prevention &amp; Control of Pollution) Act, 1974 be issued to the industry to seal <span style="mso-bidi-font-weight: bold;">one soft flow of 450 Kgs and 01 soft flow of 250 Kgs i.e. total 05 chambers </span>and suitable amount of Environmental Compensation be imposed on the industry due to de-sealing of its dyeing machinery at its own.</span></p> <p><strong>(Competency: SEE, ZO-II, Ludhiana)</strong></p>
Inspection: false
Inspection Note:
Officer: PPCB088
Reject: false
Reject Note:
Role: RO AEE Jaspal Singh