Show ApplicationProcessingDetails

Id: 21505645
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-03-21 18:03:07.523
File Note: <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">It is submitted that the hospital has applied for fresh consent to operate under Air (Prevention &amp; Control of Pollution) Act, 1981 &amp; Water (Prevention &amp; Control of Pollution) Act, 1974 along with copy of Agreement with CBWTF, Bed Capacity Certificate.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: .5in; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital has deposited Rs. 13,000/- (including Rs. 2000/- as NOC regularization fee) vide UTR No. 000124335393 dated 06.10.2022 under Water Act, 1974, Rs. 11,500/- (including Rs. 500 as application form fee) vide UTR No. 000124335832 dated 06.10.2022 under Air Act, 1981, Rs. 4000/- vide No. 318106516 dated 17.03.2023 penalty under Water Act, 1974 and Rs. Rs. 4000/- vide No. 324891471 dated 17.03.2023 penalty under Air Act, 1981, which is adequate up to 30/09/2027. </span></p> <p class="MsoListParagraph" style="margin-left: 1.0in; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital has submitted feasibility report and completion certificate regarding installation of ETP of capacity @ 05 KLD consisting of components Bar Screen &ndash; Collection Tank &ndash; Primary Clarifier &ndash; Aeration Tank &ndash; Multigrade Filter - Activated Carbon Filter and Sludge Drying Beds &ndash; Outlet.</span></p> <p class="MsoListParagraph" style="margin-left: 1.0in; text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l2 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital has submitted CBWTF agreement with M/s Amritsar Envirocare regarding lifting of bio medical waste of 15 no. beds valid upto 31.10.2026<span style="color: red;"> </span></span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The Hospital was visited by undersigned on 15/03/2023 and observed as under:-</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The Hospital comprising of 15 beds and is engaged in providing medical health services.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital has installed pre-treatment equipment in Laboratory and Operation Theatre consisting of Sodium Hypochlorite Solution.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The Hospital has installed ETP cum STP to treat the combined effluent, with outlet onto land for plantation, however same was not in operation as per availability of effluent at inlet. ETP cum STP consist of components Bar Screen &ndash; Collection Tank &ndash; Primary Clarifier &ndash; Aeration Tank &ndash; Pressure Sand Filter - Activated Carbon Filter &ndash; Outlet. </span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital has installed pre - treatment in Laboratory and Operation Theatre with the help of Sodium Hypochlorite Solution.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The HCF has provided color coded bins for segregation, collection of Bio-Medical Waste and segregation of Bio-Medical Waste was according to color codes.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The HCF has provided needle destroyer for shredding of needles.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The HCF is lifting its Bio-Medical Waste to CBMWTF and maintaining the record of the same.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The HCF has provided final collection room for storage of bio medical waste generated from its premises. </span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">No Bio-Medical Waste found mixed with general waste.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-justify: inter-ideograph; text-indent: -.25in; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">10.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital has installed D.G. set of capacity 25 KVA, which is fitted with canopy and stack of adequate height.<span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp;&nbsp; </span></span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; text-indent: .5in; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The hospital is having bed capacity of 15 beds and competency to decide the case lies with Environmental Engineer.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-justify: inter-ideograph; line-height: 130%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>Keeping in view of above, it is recommended that the fresh consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 may be granted to the hospital up to 30/09/2027 with suitable terms &amp; conditions along with special conditions that :-</span></p> <p class="MsoListParagraph" style="margin-left: .75in; text-align: justify; text-justify: inter-ideograph; text-indent: -.5in; line-height: 130%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif';">The hospital will get effluent sample (combined liquid and domestic effluent) analyzed from an approved lab of the Board within 01month.</span></p> <p class="MsoListParagraph" style="margin-left: .75in; text-align: justify; text-justify: inter-ideograph; text-indent: -.5in; line-height: 130%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif';">The hospital shall install flow meter at the inlet and outlet of the ETP and shall maintain record regarding the same. </span></p> <p class="MsoListParagraph" style="margin-left: .75in; text-align: justify; text-justify: inter-ideograph; text-indent: -.5in; line-height: 130%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif';">The hospital shall submit building plan approved from the Govt. authority to this office within 01 month. </span></p> <p class="MsoListParagraph" style="margin-left: .75in; text-align: justify; text-justify: inter-ideograph; text-indent: -.5in; line-height: 130%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif';">The hospital will renew its agreement time to time made with Common Bio Medical Waste Treatment Facility well before its expiry and submit the copy of same in this office.</span></p> <p class="MsoListParagraph" style="margin-left: .75in; text-align: justify; text-justify: inter-ideograph; text-indent: -.5in; line-height: 130%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 130%; font-family: 'Tahoma','sans-serif';">The HCF shall comply vide Head Office, no. 468 dated 31/08/2021 issued by Punjab Pollution Control Board.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB149
Reject: false
Reject Note:
Role: RO AEE Anish Sharma