| File Note: |
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The industry is a large scale dyeing unit and was granted consent to Operate under Air (Prevention & Control of Pollution) Act, 1981 upto 31.03.2023. Now, it has applied for renewal of consent under Air Act, 1981. The industry was visited by the AEE on 20.03.2023 and it was observed as under:- </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The industry was in operation during visit and engaged in dyeing and printing. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The air emission samples were collected by the PBTI, Mohali on 08.02.2023 and as per analysis report the conc. of SPM is within the prescribed limit of the Board. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The industry has installed 3 boilers of capacity @ 30 TPH, 14 TPH and 6 TPH. The boiler of 30 TPH capacity is equipped with Electrostatic Precipitator as APCD along with stack of adequate height and proper sampling arrangements. The other two boiler of capacity 14 TPH and 6 TPH have been provided with cyclone separator as APCD and common stack of adequate height and sampling arrangements. During the visit both these boilers (14 TPH and 6 TPH) were non-operational and representative of the industry informed that they are not being operated since long due to low operating pressure of these boilers. Rice husk is used as fuel by the industry. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The industry has also installed 1 no. Thermopack of 2000000 Kcal/hour. Cyclone separator along with stack of adequate height and proper sampling arrangements have been provided. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">As per the report received from PBTI, Mohali vide dated 17.02.2023, the concentration of SPM in the 30 TPH boiler is 23.3 mg/Nm3 which is within the limits. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The industry has also installed 3 no. DG sets of capacity 1000 KVA each with canopy and adequate stack height. </span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in 0in .25in;"><!-- [if !supportLists]--><span style="mso-bidi-font-size: 11.0pt;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">The industry is complying with the various provisions of Air Act, 1981.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">In view of above report by Regional office, if approved, the validity of consent to operate granted to the industry under Air Act, 1981 may be further extended upto 31.03.2025.</span></p>
<p class="ydp8b25cf8eyiv6589084485ydp48a32f10msonormal" style="margin: 0in; text-align: justify; background: white;"><span style="font-family: 'Arial',sans-serif; color: black; mso-color-alt: windowtext;">Competency – Chairman of the Board</span></p> |