<p class="MsoNormal" style="text-align: justify;"><span style="mso-tab-count: 1;"> </span><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';">It is intimated that the industry is small scale red category unit. The industry is engaged in manufacturing of scaffolding. The industry has applied for fresh consent to operate under Water Act, 1974 & Air Act, 1981.<span style="mso-spacerun: yes;"> </span>The industry has submitted lease agreement as proof of date of commissioning of the industry, as per which the industry is commissioned in year December, 2022. The industry has deposited Rs. 54,500/- vide UTR No. 527807648 dated 31.03.2023 (Rs. 32400/- water, Rs. 21,600/- NOC regularization fees, Rs. 32400/- vide UTR No. 389343053 dated 31.03.2023 under Air Act, 1981 against the fixed assets of Rs. 523.54/- Lacs which is adequate upto 30.06.2024.</span></p>
<p class="MsoNormal" style="text-align: justify;"><span style="font-size: 12.0pt; line-height: 115%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 1;"> </span>The site of industry was visited by the AEE of this office on 04.04.2023 and it was observed as under :-</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt .75in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry was in operation during visit and engaged in manufacturing of scaffolding with the help of electroplating process. The industry has not started the operation of electroplating process yet.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt .75in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry has installed 4 no. new zinc barrels for the zinc plating process.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -.25in; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt .75in;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry has signed agreement with CETP (M/s JBR Technology Pvt Ltd, D-260-61, Focal Point, Phase -8, Ludhiana) @ 25000 Ltr/month for lifting of trade effluent generated from process. </span></p>
<p class="Default" style="margin-left: .75in; text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Tahoma; color: windowtext; mso-bidi-language: AR-SA;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="color: windowtext; mso-bidi-language: AR-SA;">The industry has provided new water meter on its fresh water supply line in process area. </span></p>
<p class="Default" style="text-align: justify; text-indent: -.25in; mso-list: l0 level1 lfo1; margin: 5.9pt 5.0pt .0001pt .75in;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="color: windowtext; mso-bidi-language: AR-SA;">The industry has been advised to maintain the record of fresh water consumed in process area and trade effluent lifted to CETP operator. </span></p>
<p class="TableParagraph" style="text-align: justify; text-indent: -22.5pt; mso-list: l0 level1 lfo1; margin: 0in 4.9pt .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin;">The industry has provided one storage tank of capacity 5000 Ltr for storage of effluent generated from the process.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -22.5pt; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: black;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">Domestic effluent is being discharge into sewer.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -22.5pt; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: black;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry has installed one oil fired furnace with adequate stack height and one induction billet heater.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -22.5pt; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: black;"><span style="mso-list: Ignore;">9.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry has installed one D.G set of capacity 500 KVA with canopy and adequate stack height.</span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -22.5pt; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: black;"><span style="mso-list: Ignore;">10.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry has submitted building plan from Architect approved by the Director of Factory, Punjab. </span></p>
<p class="MsoNormal" style="text-align: justify; text-indent: -22.5pt; line-height: normal; mso-list: l0 level1 lfo1; margin: 0in 0in .0001pt 58.5pt;"><!-- [if !supportLists]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; color: black;"><span style="mso-list: Ignore;">11.<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif';">The industry is located in designated industrial zone i.e. Industrial Area –C as per Khasra Number mention in the Gazzete Notification.</span></p>
<p class="MsoNormal" style="text-align: justify; line-height: normal; margin: 0in 0in .0001pt .5in;"><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;"> </span></p>
<p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-font-weight: bold;"><span style="mso-tab-count: 1;"> </span>Keeping in view of above, it is recommended that consent to operate under Water Act, 1974 & Air Act, 1981 may be granted upto 30.06.2024 with usual conditions.</span></p> |