Show ApplicationProcessingDetails

Id: 21769102
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-04-13 14:57:51.131
File Note: <p class="MsoNormal" style="margin-left: 18.0pt; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: Wingdings; mso-fareast-font-family: Wingdings; mso-bidi-font-family: Wingdings;"><span style="mso-list: Ignore;">&Oslash;<span style="font: 7.0pt 'Times New Roman';">&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry is a small scale orange category unit.</span></p> <p class="MsoNormal" style="margin-left: 18.0pt; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: Wingdings; mso-fareast-font-family: Wingdings; mso-bidi-font-family: Wingdings;"><span style="mso-list: Ignore;">&Oslash;<span style="font: 7.0pt 'Times New Roman';">&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Now, the industry has applied for fresh consent to operate under Water (Prevention &amp; Control of Pollution) Act 1974 and Air (Prevention and Control of Pollution) Act, 1981 through OCMMS of the Board for manufacturing of Hawai Chapplies and Straps@ 2000 nos/day by using Raw Rubber @ 50 Kgs/day, China Clay @ 150 Kgs/day, Chemicals @ 600 Kgs/day as raw material<span style="mso-spacerun: yes;">&nbsp; </span>by installing 1 no. baby boiler, and detail of the same is as under:- </span></p> <ol style="margin-top: 0cm;" start="1" type="1"> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l3 level1 lfo2;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has deposited Rs. 42400/- i.e Rs. 29000/- under Air Act, 1981 and Rs. 10000/- under VDS scheme, Rs.2900/- as NOC regularization fee, Rs. 500/- form fee vide R.No. SBIN523088923039 dated 29.03.2023 and Rs. 39000/- i.e Rs. 29000/- under Air Act, 1981 and Rs. 10000/- under VDS scheme vide R.No. SBIN523088916133 dated 29.03.2023 against from assets of Rs. 47.65 Lacs as on 31.12.2022, which are adequate upto 30.9.2028.</span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l3 level1 lfo2;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has submitted building plans from approved architect from Director of Factories, Punjab. </span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l3 level1 lfo2;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has submitted certificate of registration Central sale Tex as per proof of date of commissioning i.e July/2003.</span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l3 level1 lfo2;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has also submitted site plan and manufacturing process, rent agreement and proprietorship certificate with the application. </span></li> </ol> <p class="MsoNormal" style="margin-left: 18.0pt; text-align: justify; text-justify: inter-ideograph; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: Wingdings; mso-fareast-font-family: Wingdings; mso-bidi-font-family: Wingdings;"><span style="mso-list: Ignore;">&Oslash;<span style="font: 7.0pt 'Times New Roman';">&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was visited by officer of this office on 12.04.2023 and it was observed <span style="mso-spacerun: yes;">&nbsp;&nbsp;</span>that :</span></p> <ol style="margin-top: 0cm;" start="1" type="1"> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l2 level1 lfo1;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry was in operation during visit and is engaged in the manufacturing hawai chappal. </span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l2 level1 lfo1;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">There is no source of trade effluent generation and only domestic effluent is discharged into sewer. </span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l2 level1 lfo1;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed 1 no. wood fired baby boiler of capacity 300 kg/day with adequate stack height. </span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l2 level1 lfo1;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed 02 no. mixture machines, 1 no. kneader machine, 03 nos. hydraulic press, 01 nos. strap press, 02 nos. cutter press, 02 no drill machines and 01 nos. compressor.<span style="mso-spacerun: yes;">&nbsp;&nbsp;&nbsp;&nbsp; </span></span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l2 level1 lfo1;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry has installed 1 no. DG set of capacity 125 KVA with canopy and adequate stack height.</span></li> <li class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%; mso-list: l2 level1 lfo1;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">The industry is complying with the condition of Water (Prevention &amp; Control of Pollution) Act, 1974 and under Air (Prevention and Control of Pollution) Act, 1981. </span></li> </ol> <p class="MsoNormal" style="line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';"><span style="mso-tab-count: 2;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>The industry is a small scale orange category unit and competency to decide such case lies with Senior Environmental Engineer, Jalandhar.</span></p> <p class="MsoNormal" style="line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">&nbsp;</span></p> <p class="MsoNormal" style="text-align: justify; text-justify: inter-ideograph; line-height: 150%;"><strong style="mso-bidi-font-weight: normal;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">Recommendation:- </span></strong><span lang="EN-US" style="font-size: 12.0pt; mso-bidi-font-size: 10.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Keeping in view of above, it is recommended that fresh consent to operate under Water<span style="mso-spacerun: yes;">&nbsp; </span>(Prevention &amp; Control of Pollution) Act 1974 and Air (Prevention and Control of Pollution) Act, 1981 may be granted to the industry upto 30.09.2028 with suitable conditions as per policy of the Board</span></p>
Inspection: false
Inspection Note:
Officer: PPCB113
Reject: false
Reject Note:
Role: RO JEE Jangir Singh