Show ApplicationProcessingDetails

Id: 21805302
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-04-18 13:30:22.588
File Note: <p class="MsoBodyText" style="text-indent: -.5in; line-height: 150%; mso-list: l0 level1 lfo1; margin: .5pt 6.0pt .0001pt 1.0in;"><!-- [if !supportLists]--><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]-->The industry is a large scale, red category unit.</p> <p class="MsoBodyText" style="text-indent: -.5in; line-height: 150%; mso-list: l0 level1 lfo1; margin: .5pt 6.0pt .0001pt 1.0in;"><!-- [if !supportLists]--><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="mso-bidi-font-weight: bold;">The</span> industry<span style="letter-spacing: .05pt;"> </span>was<span style="letter-spacing: 1.3pt;"> </span>granted<span style="letter-spacing: 1.35pt;"> </span>consent<span style="letter-spacing: 1.35pt;"> </span>to<span style="letter-spacing: 1.25pt;"> </span>operate<span style="letter-spacing: 1.3pt;"> </span>under<span style="letter-spacing: 1.3pt;"> </span>Water<span style="letter-spacing: 1.3pt;"> </span>(Prevention<span style="letter-spacing: 1.35pt;"> </span>and<span style="letter-spacing: 1.3pt;"> </span>Control<span style="letter-spacing: 1.25pt;"> </span>of<span style="letter-spacing: 1.3pt;"> </span>Pollution)<span style="letter-spacing: 1.3pt;"> </span>Act,<span style="letter-spacing: 1.4pt;"> </span>1974 vide no. CTOW/Renewal/JAL/2018/7576897 dated 26.06.2018 valid upto 31.03.2023<span style="letter-spacing: -3.3pt;"> </span>and Air<span style="letter-spacing: -.1pt;"> </span>(Prevention<span style="letter-spacing: -.05pt;"> </span>and<span style="letter-spacing: -.15pt;"> </span>Control of<span style="letter-spacing: -.2pt;"> </span>Pollution)<span style="letter-spacing: -.05pt;"> </span>Act,<span style="letter-spacing: -.1pt;"> </span>1981<span style="letter-spacing: -.1pt;"> vide no. </span>CTOA/Renewal/JAL/2018/7576865 dated 26.06.2018 valid upto 31.03.2023 with suitable and special conditions mentioned therein.</p> <p class="MsoBodyText" style="text-indent: -.5in; line-height: 150%; mso-list: l0 level1 lfo1; margin: .5pt 6.0pt .0001pt 1.0in;"><!-- [if !supportLists]--><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]-->Now, the industry has applied for renewal of consent to operate under the Water<span style="letter-spacing: .05pt;"> </span>(Prevention and Control of Pollution) Act, 1974 &amp; under the Air (Prevention and Control of Pollution) Act,<span style="letter-spacing: .05pt;"> </span>1981.</p> <p class="MsoBodyText" style="text-indent: -.5in; line-height: 150%; mso-list: l0 level1 lfo1; margin: .5pt 6.0pt .0001pt 1.0in;"><!-- [if !supportLists]--><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]--><span style="letter-spacing: -.15pt;">The industry has deposited </span>Rs. 4,20,000/- vide UTR No. N047232335022821 dated 16.02.2023 under Water Act, 1974, Rs. 4,20,000/- vide UTR No. N047232335022824 dated 16.02.2023<span style="mso-spacerun: yes;">&nbsp;&nbsp; </span>under Air Act, 1981 and Rs. 72000/- vide UTR No. N047232335022819 dated 16.02.2023 as NOC regularization fees on account of increase in fixed assets &amp; fees is adequate upto 31.03.2028.</p> <p class="MsoListParagraph" style="text-indent: -.5in; line-height: 150%; mso-list: l0 level1 lfo1; tab-stops: 67.9pt; margin: .2pt 6.0pt .0001pt 1.0in;"><!-- [if !supportLists]--><span style="font-size: 12.5pt; mso-bidi-font-size: 11.0pt; line-height: 150%;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The fixed assets of the industry have increased from Rs. 42.06 crore to 61.01 crore during<span style="letter-spacing: .05pt;"> </span>period from 2017 to 2022 and there is addition of plant &amp; machinery from Rs. 27.67 crore to Rs.45.09 crore. The industry has submitted detail of plant &amp; machinery it has added CNC turning machines, lathe machines, conveyor systems, induction hardening and auxiallry machinery<span style="letter-spacing: .05pt;"> </span>which is non-polluting in nature and is added on account of modernization.</p> <p class="MsoBodyText" style="text-indent: -.5in; line-height: 150%; mso-list: l0 level1 lfo1; margin: .5pt 6.0pt .0001pt 1.0in;"><!-- [if !supportLists]--><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><!--[endif]-->The industry was visited by officer of this office on 17.02.2023 &amp; it is observed as under:-</p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l1 level1 lfo2; margin: 0in 6.0pt .0001pt 121.5pt;"><!-- [if !supportLists]--><span style="letter-spacing: -.05pt;"><span style="mso-list: Ignore;">A.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The<span style="letter-spacing: -.1pt;"> </span>industry<span style="letter-spacing: -.15pt;"> </span>was<span style="letter-spacing: -.05pt;"> </span>in<span style="letter-spacing: -.05pt;"> </span>operation during<span style="letter-spacing: -.15pt;"> </span>visit.</p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l1 level1 lfo2; margin: 2.1pt 6.0pt .0001pt 121.5pt;"><!-- [if !supportLists]--><span style="letter-spacing: -.05pt;"><span style="mso-list: Ignore;">B.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry generates domestic effluent and it has installed the STP consisting of components such as Oil &amp; Grease trap, Equalization tank, Tube-settler, Bio reactors, Secondary tube settler, filters, final outlet and same was found in<span style="letter-spacing: -.1pt;"> </span>operation<span style="letter-spacing: -.15pt;"> </span>during<span style="letter-spacing: .05pt;"> </span>visit.</p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l1 level1 lfo2; margin: 0in 6.0pt .0001pt 121.5pt;"><!-- [if !supportLists]--><span style="letter-spacing: -.05pt;"><span style="mso-list: Ignore;">C.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The<span style="letter-spacing: .05pt;"> </span>effluent<span style="letter-spacing: .05pt;"> </span>sample was collected from the<span style="letter-spacing: .05pt;"> </span>outlet of STP<span style="letter-spacing: .05pt;"> </span>was collected<span style="letter-spacing: .05pt;"> </span>during visit and<span style="letter-spacing: 3.4pt;"> </span>as per sample<span style="letter-spacing: .05pt;"> </span>analysis report, pH- 7.9 mg/l, COD-192 mg/l, BOD-38 mg/l, TSS-26 mg/l, TDS 904 mg/l O&amp;G-6 mg/l which<span style="letter-spacing: .05pt;"> </span>are<span style="letter-spacing: -.05pt;"> </span>within<span style="letter-spacing: -.05pt;"> the </span>limit<span style="letter-spacing: .05pt;"> </span>prescribed<span style="letter-spacing: -.1pt;"> </span>by Board. The<span style="letter-spacing: -.15pt;"> </span>industry<span style="letter-spacing: -.15pt;"> </span>has<span style="letter-spacing: -.05pt;"> </span>installed<span style="letter-spacing: -.05pt;"> </span>water<span style="letter-spacing: -.05pt;"> </span>meter<span style="letter-spacing: -.05pt;"> </span>at<span style="letter-spacing: -.15pt;"> </span>final<span style="letter-spacing: -.1pt;"> </span>outlet<span style="letter-spacing: -.05pt;"> </span>of<span style="letter-spacing: -.05pt;"> </span>STP<span style="letter-spacing: -.05pt;">.</span></p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l1 level1 lfo2; margin: 1.95pt 6.0pt .0001pt 121.5pt;"><!-- [if !supportLists]--><span style="letter-spacing: -.05pt;"><span style="mso-list: Ignore;">D.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]-->The<span style="letter-spacing: -.15pt;"> </span>domestic<span style="letter-spacing: -.1pt;"> </span>effluent is<span style="letter-spacing: -.2pt;"> </span>being discharged<span style="letter-spacing: -.2pt;"> </span>onto<span style="letter-spacing: -.05pt;"> </span>land<span style="letter-spacing: -.05pt;"> </span>for<span style="letter-spacing: -.1pt;"> </span>plantation<span style="letter-spacing: -.1pt;"> </span>through<span style="letter-spacing: -.2pt;"> </span>STP.</p> <p class="MsoListParagraph" style="line-height: 150%; mso-list: l1 level1 lfo2; margin: 2.1pt 6.0pt .0001pt 121.5pt;"><!-- [if !supportLists]--><span style="letter-spacing: -.05pt;"><span style="mso-list: Ignore;">E.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has installed 5 no. Induction/tempering Machines which are electrically operated, CNC Machines and General Lathe<span style="letter-spacing: .05pt;"> </span>Machine.<span style="letter-spacing: -.05pt;"> </span>The<span style="letter-spacing: -.05pt;"> </span>industry<span style="letter-spacing: -.1pt;"> </span>has installed 2<span style="letter-spacing: -.15pt;"> </span>no. D.G<span style="letter-spacing: -.15pt;"> </span>sets<span style="letter-spacing: -.1pt;"> </span>with<span style="letter-spacing: -.05pt;"> </span>canopies.</p> <p class="MsoBodyText" style="line-height: 150%; margin: 0in 6.0pt .0001pt 27.0pt;"><strong style="mso-bidi-font-weight: normal;">Recommendation</strong>:- Keeping in view of above, it is recommended that consent to operate<span style="letter-spacing: .05pt;"> </span>under Water (Prevention and Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of<span style="letter-spacing: .05pt;"> </span>Pollution) Act, 1981 may be renewed to the industry upto 31-03-2028 with suitable conditions as <span style="letter-spacing: -3.3pt;"><span style="mso-spacerun: yes;">&nbsp;</span></span>per<span style="letter-spacing: -.05pt;"> </span>policy<span style="letter-spacing: -.1pt;"> </span>of the<span style="letter-spacing: -.05pt;"> </span>Board.</p>
Inspection: false
Inspection Note:
Officer: PPCB135
Reject: false
Reject Note:
Role: RO AEE Bachan Pal Singh