Show ApplicationProcessingDetails

Id: 21809549
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-04-18 16:56:42.112
File Note: <p class="MsoNormal" style="margin-bottom: 12.0pt; text-align: justify; text-indent: 1.0in; line-height: 115%;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">To verify the present compliance, undersigned has visited the industry on <strong>17.04.2023</strong> and it was observed as under:</span></p> <p class="MsoListParagraphCxSpFirst" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 12.0pt -.9pt .0001pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">The industry was in operation and engaged in the business of manufacturing of Billets (With CCM Plant) @ 84 MTD. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in 0in 10.0pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">The industry has installed induction furnace of capacity 7 TPH equipped with APCD and was found in operation. Adequate suction was observed at the side hood. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in 0in 10.0pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">There was problem of dust pollution in the industrial premises due to un-stabilized movement area. It has provided interlocking tiles only at the entrance.</span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in -.9pt .0001pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">The industry has installed spark arrestor followed by bag filter houses as APCD to control the air emissions from the furnace as per design evolved by PSCST, Chandigarh, which was also in operation. The industry has also obtained completion certificate from PSCST, Chandigarh vide no. <strong>212 dated 20/06/2019</strong>. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in -.9pt .0001pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">The industry has installed 2 no. DG set of capacity 180 KVA and 200 KVA, which are equipped with canopies and stack of adequate heights. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in -.9pt .0001pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">No water is used in the process, so no trade effluent is generated. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in -.9pt .0001pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">Domestic effluent is discharged onto land for plantation/Irrigation after passing through septic tank. </span></p> <p class="MsoListParagraphCxSpMiddle" style="mso-add-space: auto; text-indent: -27.0pt; line-height: 115%; mso-pagination: widow-orphan; mso-list: l0 level1 lfo1; text-autospace: ideograph-numeric ideograph-other; margin: 0in -.9pt .0001pt 27.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Bookman Old Style','serif'; mso-fareast-font-family: 'Bookman Old Style'; mso-bidi-font-family: 'Bookman Old Style';"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">The industry was guided to comply with directions/suggestions of PSCST, Chandigarh given in SOPs for operation of APCD and also guided to maintain the required data. </span></p> <p class="MsoListParagraph" style="text-indent: 1.0in; line-height: 115%; margin: 12.0pt -.9pt 12.0pt 0in;"><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">In view of the above, it is recommended that t</span><span lang="EN-US" style="font-family: 'Bookman Old Style','serif'; mso-bidi-font-family: Arial;">he industry may be granted renewal of </span><span lang="EN-US" style="font-family: 'Bookman Old Style','serif';">consent to operate under the Water (Prevention &amp; Control of Pollution) Act, 1974 <strong>upto 30/09/2026</strong><strong style="mso-bidi-font-weight: normal;"> </strong><span style="mso-bidi-font-weight: bold;">and 'Consent to Operate' under Air (Prevention &amp; Control of Pollution) Act, 1981 may be granted for </span><strong style="mso-bidi-font-weight: normal;">1 year i.e. upto 31.03.2024 </strong><span style="mso-bidi-font-weight: bold;">with conditions proposed earlier and special condition that it shall stabilize its entire movement area to mitigate dust pollution.</span></span></p>
Inspection: false
Inspection Note:
Officer: PPCB134
Reject: false
Reject Note:
Role: RO AEE Rubal Goyal