Show ApplicationProcessingDetails

Id: 21813475
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-04-19 10:32:33.843
File Note: <p class="MsoBodyText" style="margin-right: 18.8pt; text-indent: 36.0pt; line-height: 150%;"><span style="mso-font-width: 110%;">It is submitted that the industry was earlier granted consent to operate<span style="letter-spacing: .05pt;"> </span>under Water (Prevention &amp; Control of Pollution) Act 1974 and Air (Prevention and<span style="letter-spacing: .05pt;"> </span>Control<span style="letter-spacing: 1.0pt;"> </span>of<span style="letter-spacing: 1.0pt;"> </span>Pollution)<span style="letter-spacing: 1.0pt;"> </span>Act,<span style="letter-spacing: .95pt;"> </span>1981<span style="letter-spacing: 1.0pt;"> </span>No. CTOW/Renewal/JAL/2018/7962236 dated 16.07.2018 valid upto 30.06.2023 and No. CTOA/Renewal/JAL/2018/7962162 dated 16.07.2018 valid upto 30.06.2023.</span></p> <p class="MsoBodyText" style="margin-right: 18.55pt; text-indent: 72.0pt; line-height: 150%;"><span style="mso-font-width: 115%;">Now,<span style="letter-spacing: .05pt;"> </span>the<span style="letter-spacing: .05pt;"> </span>industry<span style="letter-spacing: .05pt;"> </span>has<span style="letter-spacing: .05pt;"> </span>applied<span style="letter-spacing: .05pt;"> </span>for<span style="letter-spacing: .05pt;"> </span>renewal<span style="letter-spacing: .05pt;"> </span>of<span style="letter-spacing: .05pt;"> </span>consent<span style="letter-spacing: .05pt;"> </span>to operate<span style="letter-spacing: .05pt;"> </span><span style="letter-spacing: -.05pt;">under</span><span style="letter-spacing: -.25pt;"> </span><span style="letter-spacing: -.05pt;">Water</span><span style="letter-spacing: -.25pt;"> </span><span style="letter-spacing: -.05pt;">(Prevention</span><span style="letter-spacing: -.25pt;"> </span>&amp;<span style="letter-spacing: -.25pt;"> </span>Control<span style="letter-spacing: -.3pt;"> </span>of<span style="letter-spacing: -.25pt;"> </span>Pollution)<span style="letter-spacing: -.25pt;"> </span>Act<span style="letter-spacing: -.25pt;"> </span>1974<span style="letter-spacing: -.15pt;"> </span>and<span style="letter-spacing: -.3pt;"> </span>Air<span style="letter-spacing: -.25pt;"> </span>(Prevention<span style="letter-spacing: -.25pt;"> </span>and<span style="letter-spacing: -2.95pt;"> </span>Control of Pollution) Act, 1981 through OCMMS. The industry has deposited Rs.94500/- vide R.N. N095232402439392 dated 05.04.2023 under Water Act, 1974 and Rs.100600/- (Including Rs. 5600/- as NOC fee and Rs. 500/- as application form fee) vide R.N. N095232402449841 dated 05.04.2023 under Air Act, 1981 which is adequate upto 30.06.2028.</span></p> <p class="MsoBodyText" style="margin-right: 18.55pt; text-indent: 72.0pt; line-height: 150%;"><span style="mso-font-width: 115%;">The industry was visited by officer of this office on 18.04.2023 and during visit it was observed that the industry was in operation and is<span style="letter-spacing: .05pt;"> </span>engaged<span style="letter-spacing: 2.35pt;"> </span>in<span style="letter-spacing: 2.4pt;"> </span>the<span style="letter-spacing: 2.35pt;"> </span>process of<span style="letter-spacing: 2.4pt;"> </span>castings<span style="letter-spacing: 2.4pt;"> </span>of<span style="letter-spacing: 2.35pt;"> </span>diesel<span style="letter-spacing: 2.4pt;"> </span>engine<span style="letter-spacing: 2.2pt;"> </span>parts.<span style="letter-spacing: 2.4pt;"> </span>The<span style="letter-spacing: 2.35pt;"> </span>industry<span style="letter-spacing: -2.9pt;"> </span>has installed one induction furnace of capacity 0.500 TPH with bag filter house as APCD and 02 nos. induction furnaces of capacity 0.750 of capacity with bag house filter as APCD. The industry has installed 1 no. shot<span style="letter-spacing: .05pt;"> </span>blasting machine with bag house filter as APCD. The industry has installed 1 no.<span style="letter-spacing: .05pt;"> </span>DG set of capacity 125 KVA with canopy. There is no source of generation<span style="letter-spacing: .05pt;"> of </span>trade effluent. Domestic<span style="letter-spacing: .05pt;"> </span>effluent<span style="letter-spacing: .05pt;"> </span>is<span style="letter-spacing: .05pt;"> being </span>discharge<span style="letter-spacing: .05pt;"> </span>into<span style="letter-spacing: .05pt;"> </span>sewer.<span style="letter-spacing: .05pt;"> </span>The<span style="letter-spacing: .05pt;"> </span>industry<span style="letter-spacing: .05pt;"> </span>has<span style="letter-spacing: .05pt;"> already </span>submitted<span style="letter-spacing: .5pt;"> </span>approved<span style="letter-spacing: .55pt;"> </span>building<span style="letter-spacing: .5pt;"> </span>plan<span style="letter-spacing: .55pt;"> </span>from<span style="letter-spacing: .55pt;"> </span>Director<span style="letter-spacing: .55pt;"> </span>of<span style="letter-spacing: .55pt;"> </span>Factories.</span></p> <p class="MsoBodyText" style="text-indent: 72.0pt; line-height: 150%; margin: .15pt 18.8pt .0001pt 19.6pt;"><span style="mso-font-width: 115%;">The<span style="letter-spacing: .05pt;"> </span>industry<span style="letter-spacing: .05pt;"> </span>is small scale orange category and the competency of case lies with Senior Environmental Engineer,<span style="letter-spacing: .05pt;"> </span>Jalandhar. </span></p> <p class="MsoBodyText" style="text-indent: 72.0pt; line-height: 150%; margin: .15pt 18.8pt .0001pt 19.6pt;"><span style="mso-font-width: 110%;">Keeping in view of above, it is recommended that consent to<span style="letter-spacing: .05pt;"> </span>operate<span style="letter-spacing: .05pt;"> </span>under<span style="letter-spacing: .05pt;"> </span>Water<span style="letter-spacing: .05pt;"> </span>(Prevention<span style="letter-spacing: .05pt;"> </span>&amp;<span style="letter-spacing: .05pt;"> </span>Control<span style="letter-spacing: .05pt;"> </span>of<span style="letter-spacing: .05pt;"> </span>Pollution)<span style="letter-spacing: .05pt;"> </span>Act<span style="letter-spacing: .05pt;"> </span>1974<span style="letter-spacing: .05pt;"> </span>and<span style="letter-spacing: .05pt;"> </span>Air<span style="letter-spacing: -2.8pt;"> </span>(Prevention<span style="letter-spacing: 2.45pt;"> </span>and<span style="letter-spacing: 2.5pt;"> </span>Control<span style="letter-spacing: 2.5pt;"> </span>of<span style="letter-spacing: 2.5pt;"> </span>Pollution)<span style="letter-spacing: 2.5pt;"> </span>Act,<span style="letter-spacing: 2.45pt;"> </span>1981<span style="letter-spacing: 2.65pt;"> </span>may<span style="letter-spacing: 2.45pt;"> </span>be<span style="letter-spacing: 2.5pt;"> </span>granted<span style="letter-spacing: 2.5pt;"> </span>upto<span style="letter-spacing: 2.5pt;"> </span>30.06.2028<span style="letter-spacing: -2.8pt;"> </span>with<span style="letter-spacing: .95pt;"> </span>usual<span style="letter-spacing: .95pt;"> </span>conditions and with special condition that the industry will gets its stack emission sample analyzed from Board&rsquo;s Lab within 01 month.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB076
Reject: false
Reject Note:
Role: RO AEE Sandeep Kaur