Show ApplicationProcessingDetails

Id: 21836359
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-04-20 18:30:05.981
File Note: <p class="MsoBodyText" style="text-align: justify; margin: .05pt 14.75pt .0001pt 10.45pt;"><span lang="EN-US">It<span style="letter-spacing: .05pt;"> </span>is<span style="letter-spacing: .05pt;"> </span>intimated<span style="letter-spacing: .05pt;"> </span>that<span style="letter-spacing: .05pt;"> </span>the<span style="letter-spacing: .05pt;"> </span>industry<span style="letter-spacing: .05pt;"> </span>is<span style="letter-spacing: .05pt;"> </span>small<span style="letter-spacing: .05pt;"> </span>scale,<span style="letter-spacing: .05pt;"> </span>orange<span style="letter-spacing: .05pt;"> </span>category unit. Earlier the industry was granted consent to operate under Water (Prevention &amp;<span style="letter-spacing: .05pt;"> </span>Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 which are valid<span style="letter-spacing: .05pt;"> </span>upto<span style="letter-spacing: .05pt;"> </span>30.09.2023 respectively for manufacturing of C I Castings And Valves Cocks @ 18 MTD by using Pig Iron And Scarp @ 18 MTD as raw material <span style="mso-spacerun: yes;">&nbsp;</span>with 1 no. Induction furnace 0.500 TPH, 1 no.<span style="mso-spacerun: yes;">&nbsp; </span>copula furnace<span style="mso-spacerun: yes;">&nbsp; </span>of capacity 3 MT and 1 no. shot blast machine.</span></p> <p class="MsoBodyText" style="margin-right: 14.8pt; text-align: justify; text-indent: 49.55pt;"><span lang="EN-US">Now the industry has applied for varied of consent to operate under Water (Prevention &amp;<span style="letter-spacing: .05pt;"> </span>Control of Pollution) Act 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 as amended in 1987 for manufacturing of C I Castings and Valves Cocks @ 18 MTD by using Pig Iron And Scarp @ 18 MTD as raw material <span style="mso-spacerun: yes;">&nbsp;</span>with 3 nos. Induction furnace 0.500 TPH and 0.300 TPH, 4 nos. shot blast machine, 1 no. powder coating machine. </span></p> <p class="MsoBodyText" style="margin-right: 14.8pt; text-align: justify; text-indent: 49.55pt;"><span lang="EN-US">The industry has increase details in CA certificate from Rs 55.17 lacs to 185.86 lacs. The industry has given details regarding increase details in its application. The industry has also installed other non-polluting machinery and general machines. </span></p> <p class="MsoBodyText" style="margin-right: 14.8pt; text-align: justify; text-indent: 49.55pt;"><span lang="EN-US">The industry has deposited </span><span lang="EN-US" style="font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';">Rs. 42000/- vide UTR no. P095230232332359 dated 05.04.2023 under Water Act 1974, Rs. 42000/- vide UTR no. P095230232338030 dated 05.04.2023 under Air (Prevention and Control of Pollution) Act, 1981,Rs. 4800 vide R/No. P095230232338030 as NOC fee Adequate upto 30.09.2028. <span style="mso-spacerun: yes;">&nbsp;</span></span></p> <p class="MsoBodyText" style="margin-right: 14.8pt; text-align: justify; text-indent: 49.55pt;"><span lang="EN-US">The industry was visited by the officer of this office on 20.04.2023 and it was observed that the<span style="letter-spacing: -2.85pt;"> </span>industry was in operation during the visit. The industry has installed 3 nos. Induction furnace 0.500 TPH and 0.300 TPH, 4 nos. shot blast machine with bag filter house with APCD and 1 no. powder coating booth. There is no generation of<span style="letter-spacing: 3.0pt;"> </span>any trade effluent. Domestic effluent is being discharged<span style="letter-spacing: .05pt;"> </span>into<span style="letter-spacing: -.05pt;"> </span>sewer. The industry has installed 2 nos. DG sets of capacity 75 KVA each with canopy. </span></p> <p class="MsoBodyText" style="margin-right: 14.8pt; text-align: justify; text-indent: 49.55pt;"><span lang="EN-US"><span style="mso-spacerun: yes;">&nbsp;</span>The industry is complying with Water (Prevention &amp; Control of Pollution) Act, 1974 as amended in 1988 and Air (Prevention &amp; Control of Pollution) Act, 1981 as amended in 1987. </span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: 49.55pt; margin: .05pt 14.75pt .0001pt 10.45pt;"><span lang="EN-US">Keeping in<span style="letter-spacing: .05pt;"> </span>view of above,<span style="letter-spacing: .05pt;"> </span>it<span style="letter-spacing: .05pt;"> </span>is<span style="letter-spacing: .05pt;"> </span>recommended<span style="letter-spacing: .05pt;"> </span>that<span style="letter-spacing: .05pt;"> </span>the<span style="letter-spacing: .05pt;"> </span>consent<span style="letter-spacing: .05pt;"> </span>to<span style="letter-spacing: .05pt;"> </span>operate under<span style="letter-spacing: .05pt;"> </span>Water<span style="letter-spacing: .05pt;"> </span>(Prevention &amp; Control of Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981<span style="letter-spacing: .05pt;"> </span>may be granted to the industry upto 30.09.2028 with suitable conditions as per policy of the Board.<span style="letter-spacing: .05pt;"> </span>(Competency<span style="letter-spacing: -.2pt;"> </span></span><span lang="EN-US" style="font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';">Senior Environmental Engineer<span style="letter-spacing: .1pt;"> </span>of<span style="letter-spacing: -.1pt;"> </span>the Board</span><span lang="EN-US">).</span></p>
Inspection: false
Inspection Note:
Officer: PPCB113
Reject: false
Reject Note:
Role: RO JEE Jangir Singh