Show ApplicationProcessingDetails

Id: 21840912
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-04-21 10:34:15.972
File Note: <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: 150%; background: white;"><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-language: PA;">During visited on 12.04.2023 effluent sample were collected from the outlet of the ETP. As per analysis report, the concentration of various parameters outlet are pH= 7.9, TSS =18 mg/l, TDS = 518 mg/l, COD = 81 mg/l, BOD =16 mg/l and O&amp;G = BDL mg/l, as per the report all the parameters were found within the limits prescribed by the Board.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: normal; background: white;"><span lang="EN-IN" style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-language: PA;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; In view of above, it is therefore recommended that:-</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: normal; background: white;"><span lang="EN-IN" style="font-size: 12.0pt; font-family: 'Tahoma','sans-serif'; mso-bidi-language: PA;">&nbsp;</span></p> <p class="MsoListParagraph" style="mso-add-space: auto; text-align: justify; text-indent: -33.0pt; line-height: 150%; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in .0001pt 51.0pt;"><!-- [if !supportLists]--><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma; mso-bidi-language: PA;">1.<span style="font-variant-numeric: normal; font-variant-east-asian: normal; font-stretch: normal; font-size: 7pt; line-height: normal; font-family: 'Times New Roman';"> &nbsp; </span></span><span lang="EN-IN" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-bidi-language: PA;">Consent to operate under Air (Prevention &amp; Control of Pollution) Act, 1981 may be granted to the industry for the period of six months with usual conditions.</span></p> <p class="MsoListParagraph" style="mso-add-space: auto; text-align: justify; text-indent: -33.0pt; line-height: 150%; mso-list: l0 level1 lfo1; background: white; margin: 0in 0in .0001pt 51.0pt;"><span style="font-family: Tahoma, 'sans-serif'; font-size: 12pt;">2.&nbsp; Directions u/s 33-A of Water (Prevention &amp; Control of Pollution) Act, 1974 may be issued to restore the electric connection of the industry temporarily for the period of further six months.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB150
Reject: false
Reject Note:
Role: RO AEE Bhisham