| File Note: |
<p class="TableParagraph" style="text-align: justify; text-indent: 35.95pt; line-height: 150%; margin: 0cm 4.95pt .0001pt 5.65pt;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%; mso-font-width: 115%;">It is intimated that the industry was earlier granted consent to operate under<span style="letter-spacing: .05pt;"> </span>Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 Vide no. CTOW/Renewal/JAL/2018/7578749 dated 12.07.2018 valid upto 30.06.2023 and Vide No. CTOA/Renewal/JAL/2018/7578700 dated 12.07.2018 valid upto 30.06.2023.</span></p>
<p class="TableParagraph" style="text-align: justify; text-indent: 35.95pt; line-height: 150%; margin: 0cm 4.95pt .0001pt 5.65pt;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%; mso-font-width: 115%;">Now, the industry has applied for renewal of consent to operate under<span style="letter-spacing: .05pt;"> </span>Water (Prevention & Control of Pollution) Act 1974 and Air (Prevention and<span style="letter-spacing: .05pt;"> </span>Control of Pollution) Act, 1981 through OCMMS. The industry has deposited Rs. 42500/- Vide R/No. KKBKH23107646447 Dated 17.04.2023 under Water Act 1974 and Rs. 42500/- (Including Rs.500/- as application form fee) vide R No. KKBKH23107646085 Dated 17.04.2023 under Air Act, 1981, which is adequate upto 30.06.2028</span></p>
<p class="TableParagraph" style="text-align: justify; text-indent: 35.95pt; line-height: 150%; margin: 0cm 4.95pt .0001pt 5.65pt;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%; mso-font-width: 115%;">The industry was visited by<span style="letter-spacing: .05pt;"> </span>the officer of this office on 20.04.2023 and it was observed that the industry was<span style="letter-spacing: -2.9pt;"> </span>in<span style="letter-spacing: 3.05pt;"> </span>operation<span style="letter-spacing: 3.05pt;"> </span>during<span style="letter-spacing: 3.05pt;"> </span>visit<span style="letter-spacing: 3.05pt;"> </span>and<span style="letter-spacing: 3.05pt;"> </span>engaged<span style="letter-spacing: 3.05pt;"> </span>in<span style="letter-spacing: 3.05pt;"> </span>manufacturing<span style="letter-spacing: 3.05pt;"> </span>of<span style="letter-spacing: 3.05pt;"> </span>casting<span style="letter-spacing: 3.05pt;"> </span>of<span style="letter-spacing: -2.9pt;"> </span>scaffolding. The industry has installed 2 no. induction furnaces of capacity 0.500 TPH and 0.300 TPH with common<span style="letter-spacing: .05pt;"> </span>bag<span style="letter-spacing: .05pt;"> </span>house<span style="letter-spacing: .05pt;"> </span>filter<span style="letter-spacing: .05pt;"> </span>as<span style="letter-spacing: .05pt;"> </span>APCD.<span style="letter-spacing: .05pt;"> </span>The industry has installed 3 no. shot blasting<span style="letter-spacing: .05pt;"> </span>machine<span style="letter-spacing: -.5pt;"> </span>with<span style="letter-spacing: -.5pt;"> </span>bag<span style="letter-spacing: -.5pt;"> </span>house<span style="letter-spacing: -.5pt;"> </span>filter<span style="letter-spacing: -.5pt;"> </span>as<span style="letter-spacing: -.5pt;"> </span>APCD.<span style="letter-spacing: -.35pt;"> </span>The<span style="letter-spacing: -.5pt;"> </span>industry<span style="letter-spacing: -.5pt;"> </span>has<span style="letter-spacing: -.5pt;"> </span>installed<span style="letter-spacing: -.45pt;"> </span>1<span style="letter-spacing: -.5pt;"> </span>no.<span style="letter-spacing: -.5pt;"> </span>powder<span style="letter-spacing: -2.95pt;"> </span>coating machine with cyclone separator. The industry has installed 04 nos. annealing furnaces with adequate stack. The industry has not installed any D.G set. The industry has already submitted<span style="letter-spacing: .05pt;"> </span>approved<span style="letter-spacing: -.55pt;"> </span>building<span style="letter-spacing: -.5pt;"> </span>plan<span style="letter-spacing: -.5pt;"> </span>from<span style="letter-spacing: -.5pt;"> </span>competent<span style="letter-spacing: -.4pt;"> </span>person<span style="letter-spacing: -.5pt;"> </span>under<span style="letter-spacing: -.5pt;"> </span>Factory<span style="letter-spacing: -.35pt;"> </span>Act,<span style="letter-spacing: -.5pt;"> </span>Punjab.<span style="letter-spacing: -.4pt;"> </span></span></p>
<p class="TableParagraph" style="text-align: justify; text-indent: 35.95pt; line-height: 150%; margin: 0cm 4.95pt .0001pt 5.65pt;"><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; line-height: 150%; mso-font-width: 115%;">The industry is small<span style="letter-spacing: .05pt;"> </span>scale<span style="letter-spacing: 1.25pt;"> </span>orange<span style="letter-spacing: 1.25pt;"> </span>category<span style="letter-spacing: 1.2pt;"> </span>and<span style="letter-spacing: 1.2pt;"> </span>the<span style="letter-spacing: 1.25pt;"> </span>competency<span style="letter-spacing: 1.2pt;"> </span>of<span style="letter-spacing: 1.2pt;"> </span>case<span style="letter-spacing: 1.2pt;"> </span>lies<span style="letter-spacing: 1.25pt;"> </span>with<span style="letter-spacing: 1.25pt;"> </span>Senior Environmental<span style="letter-spacing: 1.3pt;"> </span>Engineer,<span style="letter-spacing: 1.3pt;"> </span>Jalandhar.</span></p>
<p><span style="font-size: 12.0pt; mso-bidi-font-size: 11.0pt; font-family: 'Cambria','serif'; mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria; mso-font-width: 115%; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">In view of above, it is recommended that the consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 may be granted upto 30.06.2028 with usual conditions and with special condition that the industry will get its stack emission samples analyzed from Board’s Lab within 01 month.</span></p> |