Show ApplicationProcessingDetails

Id: 22053349
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-05-12 22:55:24.481
File Note: <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: 72.0pt; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The rice sheller was granted &lsquo;Consents to Operate&rsquo; under the Water Act, 1974 &amp; the Air Act, 1981 for operation of Rice sheller unit with dryer section to manufacture raw rice with dryer @ 05 TPH &amp; sorted rice @ 05 TPH vide no. CTOW/Renewal/LDH3/2019/9761394<span style="mso-tab-count: 1;">&nbsp;&nbsp;&nbsp; </span>&amp; CTOA/Renewal/LDH3/2019/9760922dated 01.05.2019, both are valid upto 30.09.2023. </span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: 72.0pt; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">Now, the rice sheller has applied for &lsquo;Consents to Operate&rsquo; under the Water (Prevention &amp; Control of Pollution) Act, 1974 &amp; the Air (Prevention &amp; Control of Pollution) Act, 1981 for operation of rice sheller unit with dryer to manufacture raw rice with dryer @ 05 TPH &amp; sorted rice @ 05 TPH. </span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; text-indent: 72.0pt; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The rice sheller has submitted C.A. certificate dated 06.05.2023 showing gross fixed assets value of Rs. 139.84 lacs, compliance of consent conditions. The industry has deposited Rs. 75,600/- vide UTR. No. 728637271 dated 10.05.2023 under Water Act, 1974 &amp; Rs. 75,600/- vide UTR. No. 577912963 dated 10.05.2023 under Air Act, 1981 adequate for period upto 30.09.2032 under both acts. </span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;"><span style="mso-tab-count: 2;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>The rice sheller was visited by AEE of this office on 10.05.2023 and it was observed as under: </span></p> <p class="MsoListParagraphCxSpFirst" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry was not in operation during visit due to labour strike in Jagraon area. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry has one shelling section and has provided cyclone as APCD and the same were in line / operation with all dust emitting points connected to the APCD. The industry has also provided stack of adequate height with APCD along with provisions to facilitate emission sample. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry has also provided one dryer section and has provided cyclone as APCD and the same were in line / operation with all dust emitting points connected to the APCD. The industry has also provided stack of adequate height with APCD along with provisions to facilitate emission sample. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry has provided wall of adequate length &amp; height with bricks around husk discharge/ storage area and wind screen of 5' height is also provided over the said wall. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry has provided brick paving at movement area of vehicles, within its premises to prevent the generation of dust emissions. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry has provided septic tank for treatment of domestic effluent with the provision to discharge the same after treatment onto land for irrigation. </span></p> <p class="MsoListParagraphCxSpMiddle" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry has made plantation along its boundary wall. </span></p> <p class="MsoListParagraphCxSpLast" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">8.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; background: white;">The industry is complying with the provisions of the Water Act, 1974 &amp; Air Act, 1981 as well as code of practice prescribed by the Govt. vide order dated 15.10.2013.</span></p> <p class="MsoNormal" style="margin-bottom: .0001pt; text-align: justify; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Keeping in view of the above, it is recommended that:</span></p> <p class="MsoListParagraph" style="margin-bottom: .0001pt; mso-add-space: auto; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif'; mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">A)<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: 'Tahoma','sans-serif';">Renewal of &lsquo;Consent to Operate&rsquo; under the Water Act, 1974 may be granted to the industry for operation of Rice sheller unit to manufacture <span style="background: white;">raw rice with dryer @ 05 TPH &amp; sorted rice @ 05 TPH</span> for period upto 30.09.2032 subject to suitable conditions. <span style="mso-spacerun: yes;">&nbsp;</span><span style="mso-spacerun: yes;">&nbsp;</span></span></p>
Inspection: false
Inspection Note:
Officer: PPCB148
Reject: false
Reject Note:
Role: RO AEE Rajpal Gill