Show ApplicationProcessingDetails

Id: 22463422
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2023-06-18 12:13:44.152
File Note: <p><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">1. Has the industry removed vegetation earlier observed in anaerobic filter tank and sludge drying beds?&nbsp;</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">2. Is the industry maintaining record w.r.t ETP operations?&nbsp;</span><span style="font-family: 'Times New Roman', 'serif'; font-size: 16px;">If so, report discrepancies, if any.</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">3. Has the industry removed wild grass and unwanted material from plantation area developed for disposal of treated effluent? </span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">4. Has proper conveyance system provide for carrying effluent from ETP to plantation area?</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">6. Is plantation area adequate to handle effluent load of ETP ?</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">7. What is means of disposal of treated domestic effluent and its adequacy?</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">8. Is the industry maintaining record w.r.t generation, storage and lifting of boiler ash? If so, report discrepancies, if any. </span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">9. <span style="mso-spacerun: yes;">&nbsp;</span>Pl request industry to submit compliance of conditions of previous consent granted to the unit.</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">10.Pl request industry to submit reply to this office letter no. 4701 dated 10.08.2022.</span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">11. Is any complaint pending against the industry? </span></p> <p class="MsoNormal" style="mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: justify; line-height: normal;"><span style="font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';">Also submit fresh recommendations in the matter.</span></p>
Inspection: false
Inspection Note:
Officer: PPCB082
Reject: false
Reject Note:
Role: RO EE Guneet Sethi