Show ApplicationProcessingDetails

Id: 24749559
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2024-01-19 16:44:36.191
File Note: <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l3 level1 lfo1; margin: .05pt 20.75pt .0001pt 37.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry is a small scale orange category unit.</span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l3 level1 lfo1; margin: .05pt 20.75pt .0001pt 37.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry was granted consent to establish (NOC) under Water (Prevention &amp; Control of Pollution) Act, 1974 and under Air (Prevention and Control of Pollution) Act, 1981 valid upto 30.06.2024 for manufacturing of castings of auto parts/tractor parts etc by using iron scrap as raw material<span style="mso-tab-count: 1;"> </span>. </span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l3 level1 lfo1; margin: .05pt 20.75pt .0001pt 37.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">Now, the industry has applied for fresh consent to operate under Water (Prevention &amp; Control of<span style="letter-spacing: -3.0pt;"> </span>Pollution) Act, 1974 and Air (Prevention &amp; Control of Pollution) Act, 1981 through OCMMS of the Board for manufacturing of castings of auto parts/tractor parts etc by using iron scrap as raw material and detail of the same is as under: </span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2; margin: .05pt 20.75pt .0001pt 55.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has Rs. 90000/- vide UTR No. N006242821172252 dated 06.01.2024 under Water Act 1974 and Rs. 90000/- vide UTR No. N006242821199448 dated 06.01.2024 under Air<span style="mso-spacerun: yes;">&nbsp; </span>Act, 1981 against the fixed assets of Rs. 572.77 lacs, which<span style="letter-spacing: -.1pt;"> </span>are adequate<span style="letter-spacing: .05pt;"> </span>upto<span style="letter-spacing: .05pt;"> </span>30.06.2029.</span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2; margin: .05pt 20.75pt .0001pt 55.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has submitted approved building plan from Competent Person under Factories Act, Punjab.</span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2; margin: .05pt 20.75pt .0001pt 55.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-spacerun: yes;">&nbsp;</span>The industry has submitted manufacturing process, registry of the land, partnership deed, MSME certificate, drawing of pollution control device with the application.</span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2; margin: .05pt 20.75pt .0001pt 55.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The project proponent has uploaded the CLU certificate issued by Punjab Government (Local Govt., Punjab) vide its memo no. PB/CLU/JUC/JALAN/2403 dated 12.01.2023 the permission has been granted for change of land use for Industry/Godown/Warehousing/Cold Storage</span><span lang="EN-US">.</span></p> <p class="Default" style="margin-left: 55.0pt; text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2;"><!-- [if !supportLists]--><span style="mso-fareast-font-family: Tahoma;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]-->The industry has submitted land use classification certificate issued from ATP, Jalandhar vide letter No. 525 dated 07.08.2023 in which mentioned that the site of the industry falls in industrial zone as per Master Plan 2009-2031.</p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2; margin: .05pt 20.75pt .0001pt 55.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has submitted compliance of the previous granted consent to establish (NOC) under Water (Prevention &amp; Control of Pollution) Act, 1974 and under Air (Prevention and Control of Pollution) Act, 1981. </span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l2 level1 lfo2; margin: .05pt 20.75pt .0001pt 55.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">7.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has submitted certification from PSCST, Chandigarh vide No. TFD/545 dated 14.12.2023 for installation of induction furnace of capacity 500 kg/heat as per Technology provided by the council.</span></p> <p class="MsoBodyText" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l1 level1 lfo3; margin: .1pt 20.7pt .0001pt 37.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;"><span style="mso-list: Ignore;">&middot;<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry was visited by the AEE of this office on<span style="letter-spacing: 3.1pt;"> </span>19.01.2024 and it was observed that:</span></p> <p class="MsoListParagraph" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo4; margin: .55pt 32.65pt .0001pt 42.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">1.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has installed one induction furnace of capacity 500 kg/heat with bag filter house as APCD with adequate stack height.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo4; margin: .55pt 32.65pt .0001pt 42.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">2.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has installed one shot blasting machine with bag filter house as APCD with adequate stack height</span></p> <p class="MsoListParagraph" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo4; margin: .55pt 32.65pt .0001pt 42.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">3.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has installed one DG set of capacity 150 KVA with canopy in its premises. </span></p> <p class="MsoListParagraph" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo4; margin: .55pt 32.65pt .0001pt 42.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">4.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry has installed other general machinery at site.</span></p> <p class="MsoListParagraph" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo4; margin: .55pt 32.65pt .0001pt 42.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">5.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">There is no source of trade effluent generation and only domestic effluent generated by the industry is discharged onto land for plantation after septic tank. Entire cooling water is being re-circulated. </span></p> <p class="MsoListParagraph" style="text-align: justify; text-indent: -18.0pt; line-height: 150%; mso-list: l0 level1 lfo4; margin: .55pt 32.65pt .0001pt 42.0pt;"><!-- [if !supportLists]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-list: Ignore;">6.<span style="font: 7.0pt 'Times New Roman';">&nbsp;&nbsp;&nbsp; </span></span></span><!--[endif]--><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;">The industry is complying with the conditions under Water (Prevention &amp; Control of Pollution) Act, 1974 and under Air (Prevention and Control of Pollution) Act, 1981.</span></p> <p class="MsoBodyText" style="margin-right: 32.7pt; text-align: justify; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-tab-count: 2;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>The industry is a small scale orange category unit and competency to decide such case lies with Senior Environmental Engineer, Zonal Office, Jalandhar.</span></p> <p class="MsoBodyText" style="margin-right: 32.85pt; text-align: justify; text-indent: 40.75pt; line-height: 150%;"><span lang="EN-US" style="font-size: 12.0pt; line-height: 150%;"><span style="mso-tab-count: 1;">&nbsp;&nbsp; </span>Keeping in view of above, it is recommended that fresh of consent to operate under Water (Prevention &amp; Control of Pollution) Act, 1974 and under Air (Prevention and Control of Pollution) Act, 1981 may be granted upto 30.09.2028 with usual condition as per policy of the Board.</span></p> <p class="MsoBodyText" style="text-align: justify; line-height: 150%; margin: .1pt 20.7pt .0001pt 0pt;"><span lang="EN-US">&nbsp;</span></p>
Inspection: false
Inspection Note:
Officer: PPCB113
Reject: false
Reject Note:
Role: RO AEE Jangir Singh