It is intimated that the industry is a medium scale red category printing unit and was earlier granted consent to operate under Water (Prevention & Control of Pollution) Act, 1974 vide no. CTOW/Renewal/LDH3/2023/23433850 dated 13.10.2023 and under Air Act, 1981 vide no. CTOA/Renewal/LDH3/2023/20530484 dated 25.10.2023 for the production of weaved & printed cloth (ladies suit & dupatta) @ 25000 meter/day with Embroidery @ 6500 meter/day and Printed Cloth (Ladies Suit & Duppata) @ 8800 meter/day with the generation of trade effluent @ 280 KLD and domestic effluent @ 20 KLD for reusing the same in the process, which were expired on 05.04.2024.
Now, the industry has applied for renewal of consent to operate under Water Act, 1974 and Air Act, 1981 for the production of weaved & printed cloth (ladies suit & dupatta) @ 25000 meter/day with Embroidery @ 6500 meter/day and Printed Cloth (Ladies Suit & Duppata) @ 8800 meter/day with the generation of trade effluent @ 280 KLD and domestic effluent @ 20 KLD for reusing the same in the process. The industry has submitted fee Rs. 2,52,000/- UTR. No. UTIBR52023082800362799 dated 28.08.2023 & Rs. 1,68,000/- vide UTR No. AXSK240880018747 dated 28.03.2024 under Water Act, 1974, Rs. 42,000/- vide UTR No. AXSK240880018870 dated 28.03.2024 as NOC regularization fee and Rs. 1,68,000/- vide UTR no. AXSK240880018902 dated 28.03.2024 under Air Act, 1981, which are adequate upto 31.12.2028 under Water Act, 1974 and 31.12.2025 under Air Act, 1981.
The industry was visited by the AEE of this office on 23.05.2024 and observed that:-
1. The industry was in operation and the same was engaged in the manufacturing, washing and printing of ladies suits.
2. The industry has installed one flat printing machine, tables for printing, power loom machines, 3 washing machines & 01 continuous washing machine within its premises.
3. The industry has installed an ETP based on ZLD for the treatment of effluent generated from washing and printing. The industry has provided collection tank for the RO permeate with provision to reuse it in the process. The industry has provided MEE for the evaporation of RO reject.
4. The industry has installed 02 no. steam boilers of capacities 3 TPH & 2.5 TPH and 01 Boiler of capacity 2 TPH with Multi cyclone separator followed by dual stage alkali scrubber as APCD. During visit, APCDs were in operation and industry was using pet coke as fuel in boilers. During visit stack was almost clear as no black smoke observed from the stack.
5. The industry has also installed 2 no. D.G sets of capacities 500 KVA and 380 KVA, which are provided with canopies and adequate stack height.
6. The industry is complying with the provisions of Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981.
In view of the above, it is recommended that consent to operate under Water (Prevention & Control of Pollution) Act, 1974 may be granted to the industry upto 30.06.2027 with usual conditions.
|