Show ApplicationProcessingDetails

Id: 25782466
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2024-05-28 13:58:34.678
File Note: Earlier the industry was granted consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 vide no. CTOW/Renewal/LDH1/2022/19237535 Date of issue: 01/09/2022 Date of expiry: 19/07/2023 and CTOA/Renewal/LDH1/2022/18779257 Date of issue: 11/10/2022 Date of expiry: 31/03/2023 for manufacturing of Non-Alloyed MS Round @ 98 TPD with one oil fired Reverberatory furnace and 1 coal fired Reverberatory furnace of capacity 5 TPH each. It is pertinent to mention here that earlier as per Govt. Notification S.O. 3250(E) dt 20.7.2022 issued by the Ministry of Environment Forest & Climate Change, Govt. of India, the unit was supposed to obtain Environmental clearance. Presently the Govt. of India vide notification no. CG-DL-E-23112023-250229 dated 22.11.2023 has exempted the said units from obtaining Environmental Clearance. Now the industry has dismantled the standby oil fired Reverberatory furnace and is carrying out all the activities related to production with the help of one coal fired Reverberatory furnace only and has applied for varied consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 for manufacturing of Non-Alloyed MS Round @ 98 TPD The industry has uploaded, CA certificate, compliance report of earlier granted consent, manufacturing process, site plan location plan. 1. The industry was not in operation during visit to the industry on 24.05.2024. 2. The industry is engaged in manufacturing of MS round. 3. The industry has installed one rolling furnaces with cyclone followed by wet scrubber as APCD with adequate stack height and proper sampling arrangements. 4. The old oil fired furnace has been dismantled by the industry, which was being used as a standby furnace. 5. The industry is maintaining the record of APCD and same was verified during visit. 6. The industry has installed one DG set of capacity 80 KVA with canopy & adequate stack height. 7. There is no source of generation of trade effluent & only domestic effluent is being discharged onto land for plantation after septic tank. In view of above, it is recommended that varied consent to operate under the Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 may be granted to the industry upto 30.09.2030 (upto adequacy of fee deposited) for manufacturing of Non-Alloyed MS Round @ 98 TPD with suitable terms and conditions and with special condition that the industry shall got its air emission analysed from Board’s lab within 3 months.
Inspection: false
Inspection Note:
Officer: PPCB092
Reject: false
Reject Note:
Role: RO AEE Deepak Chadha