File Note: The above note may kindly be perused…………………………. Previous consent was granted for discharge of trade effluent @ 720 KLD into the conveyance line of the CETP. Now applied for consent for discharge of @790 KLD…………………………. As per DEMAT certificate, the industry has shares for discharge of wastewater @ 1579 KLD in the CETP…………… The industry has installed a new machine of 600 KG capacity with 4 chambers without permission of the Board………………………….. As per GNE calculations, the wastewater discharge at the installed machinery is 810 KLD…………………….. Unit has installed excess machinery contributing to discharge of 90 KLD of wastewater compared with previous consent………………… As per decision taken by the Board on 06.05.2025, the unit cannot carryout expansion beyond the discharge for which previous consent was granted………………. Recommended to refuse the consent to operate due to above said reasons and to issue directions u/s 33-A of the Water (Prevention & Control of Pollution) Act, 1974 to seal the excess machinery installed by the unit contributing to excess discharge of 90 KLD into the CETP of 50 MLD treatment capacity……… Competency : Chairperson, PPCB