Show ApplicationProcessingDetails

Id: 30910303
Approve: false
Approve Note:
Clarification: false
Clarification Note:
Date Created: 2026-01-14 12:09:24.51
File Note: The report and recommendation of RO be perused. The industry is a small scale, red category, Dyeing unit. Earlier the industry was found using illegal fuel and effluent results were beyond permissible limits. Accordingly Directions u/s 31-A of Air (Prevention & Control of Pollution) Act, 1981 and 33-A of Water (Prevention & Control of Pollution) Act, 1974 were issued for disconnection of electric supply. There after the industry make compliance and electric connection was temporarily restored to the industry upto 31.01.2025 and CTOs were granted upto 31.01.2025. Subsequently the industry has obtained auto renewal of CTOs upto 24/07/2029 which was curtailed to 31.01.2025 vide Board letter no. 2739-40 dated 12.08.2024. As the temporary restoration period has been elapsed, therefore PSPCL Authorities were contacted and the electric connection was again disconnected vide no. 11005 dated 26.12.2025. Now the industry has applied for obtaining renewal of CTOs along with request for restoration of the electric connection. The industry has submitted consent fee which it is adequate upto 24.07.2029 under both Acts. The industry was visited by officer of Regional office on 09.01.2026 and it was observed that the industry was not in operation due to disconnection of electric supply. The industry has installed 03 nos. jet machines, 01 no. stenter machine. The industry has installed one no. wood fired thermopac of capacity 1500 U and multi-cyclone is provided as APCD. During visit wood was stored as fuel to be used in the thermopac. 4. The industry has installed ETP comprising of Collection Tank – Clarifloculator – Clarifier – Prefiltration Sump – Pressure Sand Filter – Activated Carbon Filter. 5. The industry has developed 1194 Sq. Yards of land as per Karnal Technology for the utilization of treated trade effluent. The industry has also provided land in the shape of gardening having approx. area 311 Sq.Yards for the utilization of treated trade effluent. Further the industry has also deposited B.G of Rs 1,00,000/- valid upto 11.9.2027. May if approved: 1. Directions u/s 31-A of Air (Prevention & Control of Pollution) Act, 1981 and 33-A of Water (Prevention & Control of Pollution) Act, 1974 may be issued to the PSPCL authorities for temporary restoration of electric connection of industry upto 06 months. 2. Consent to operate under Water (Prevention & Control of Pollution) Act, 1974 and Air (Prevention & Control of Pollution) Act, 1981 of the industry may be granted upto 06 months. Competency Consent : Senior Environmental Engineer Directions : Chief Environmental Engineer with concurrence from Hon'ble Chairperson.
Inspection: false
Inspection Note:
Officer: PPCB089
Reject: false
Reject Note:
Role: ZO EE Satyajeet Singh Attri