| File Note: |
Sub: Application for obtaining renewal of 'consents to operate' under the Water (Prevention & Control of Pollution) Act, 1974 and the Air (Prevention & Control of Pollution) Act, 1981 -M/s Madhav Udyog Private Limited, Rolling Divison Talwara Road,mandi Gobindgarh.
Ref: Industry's online application ID 31719559 (W) & 31716043 (A) dated 17.04.2026.
The industry has applied for obtaining renewal of ‘consents to operate' under the Water Act, 1974 and the Air Act, 1981. The application of the industry has been scrutinized and examined. The details are as under:
A General Information
(i) Date of first receipt of application.
Date of receipt of application complete in all respect. 17.04.2026
17.04.2026
(ii) Name & Address of the Industry M/s Madhav Udyog Private Limited, Rolling Divison Talwara Road, Mandi Gobindgarh.
(iii) Raw Materials / Chemicals used with quantity Ingots/ Billet/ Bloom @ 320 TPD
(iv) Products / By Products manufactured with
quantity Angle/ Channels / Beam @ 300 TPD
(v) Manufacturing Process (flow chart) (Please write the manufacturing process
clearly and do not write that the flow chart is attached) Raw Material –Cutting - Furnace Loading – heating – Rolling – Cooling – Ready
(vi) Un-depreciated Cost of fixed assets. Cost of plant & machinery.
Whether Latest C.A certificate showing Gross block of Fixed assets attached Rs. 1700.00 Lacs
Rs. 500.00Lacs
C.A. certificate as on 01.03.2026 as per CA certificate dated 18.03.2026
(vii) Consent fee
• Detail
Whether adequate or not? If yes, for How many years the same is adequate. Water consent fees: Deposited Rs. 90,000/- vide Receipt no. 782396115 dated 08.04.2026.
Air consent fee: Deposited Rs. 36000/- vide Receipt no. 730524533 dated 08.04.2026.
NOC Fees: Rs. 10,800/- vide receipt no. 782396115 dated 08.04.2026.
Penalty Fee: Rs. 1800/- (10%) for late applying of case.
Yes, adequate upto 28/02/2031 as per notification dated 29/10/2018.
(viii) Category of the Industry (Red / Orange / Green) (Green)103.3 Rolling mills (gas fired)
(ix) Scale of the industry and the detail of certificate issued by the Competent Authority regarding Scale of the
industry (Small/ Medium/ Large) Small Scale
(x) Date of commissioning Existing unit
(xi) Total Land area of the industry (Acres) Existing Unit
(xii) Number of visits carried out during the last one year One
(xiii) Source of water supply Own Tubewell
(xiv) Details of the previous consent
No. & date of consent under the Water Act, 1974
No. & date of consent under the Air Act, 1981
CTOW/Renew/FGS/2021/15412910 dated 05/04/2021, valid upto 31/12/2030.
CTOA/Renewal/FGS/2021/15412910
dated 05/04/2021, valid upto
31/12/2030.
Whether the industry is complying with all the conditions of the consent granted under the Water Act, 1974 or not? If not, mention the conditions which the industry is not complying with.
Whether the industry is complying with all the conditions of the consent granted under the Air Act, 1981 or not? If not, mention the conditions, which the industry is not complying
with. Yes
Yes
(xv) Whether environmental Audit report submitted or not? If yes, its detail. NA
(xvi) Competent Authority to decide the case and the circular no. & date vide which the Board has delegated powers to decide the
application. Environmental Engineer
B Source of Water Pollution and its Control
(i) Trade Effluent No. of outlets: The industry is not generating any trade effluent. Hence not applicable.
Quantity: N.A
• High TDS
• Low TDS
• Toxic Stream Mode of disposal : N.A
(ii) Domestic Effluent No. of outlets Quantity
Mode of disposal : One
: 3.0 KL/day
: Onto land for plantation.
(iii) Detail of mode of disposal
Land Developed – Plantation made along the boundary wall.
• Whether adequate or not : Yes
Growth/Health of plantation :Good
Hydraulic loading of wastewater KL/Bighas/day - NA
In case mode of the disposal is onto land for irrigation / plantation, give details of land availability and its adequacy.
In case, the wastewater is discharged into inland surface water, whether the industry has obtained permission from the Competent Authority of the State
or not. If yes, detail of said permission
(iv) Details of Recirculation System Cooling water
Process water 6.2 KLD
NIL
(v) Details of ETP The industry is not generating any trade
effluent and the whole cooling water is re- circulated, hence N.A.
(vi) • Whether energy meter with the ETP provided? If yes, its reading during visit.
• Whether the records regarding operation of ETP, chemicals being used, energy being consumed and sludge being generated are maintained NA NA
(vii) Whether the industry has provided a
defined facility / point for the collection of trade effluent samples. NA
(viii) Detail of last trade effluent sampling carried out.
Point of sampling Date of Sampling Capacity at which the plant was operated at the time of
sampling Conc. of pollutants(mg/l)
pH COD
mg/l BOD
mg/l TSS
mg/l O & G mg/l MLSS
mg/l MLVSS
mg/l
(ix) Whether Electro Magnetic flow meter has been The industry is not generating any trade
provided at the; effluent , hence NA
Final outlet of the ETP? If yes, and its N.A.
reading.
Point where the treated trade effluent is re- circulated back into the process and its N.A.
reading?
(x) Whether the industry has developed its own laboratory for testing of trade effluent or not? If
yes, which parameters can be analysed. NA
(x) Whether water meter has been provided at the
source of water supply or not? If yes, and its reading. Yes, provided on submersible pump
C Sources of Air Pollution and its Control:
(i) Sources of Fuel / Process Emission s No. Stea m Gen./ capaci ty Type &
Qty. of fuel to be consumed Proposed height of stack (m) APCD
Abo ve GL. Abo ve RL. Adequa cy Type
Re- heating
furnace 1 300
TPD PNG @ 12000
m3/h 30 m 20 M Yes Wet scrubber
(ii) Whether the air pollution arrangements adopted by the industry are adequate or not? Yes, adequate
(iii) Whether on line monitor has been installed or not? If yes, its detail. No
(iv) Whether the industry has developed its own laboratory for testing of pollutants in the emissions or not? If yes, which
parameters can be analyzed. No
(v) Whether the boiler furnace is based on FBC system or not? The industry has not hence not applicable installed any boiler,
(vi) Whether proper canopy has been installed with the D.G. set or not? The industry has installed 1 no. D.G. set of
capacity 200 KVA, which is provided canopy and stack of adequate height.
D Detail of hazardous wastes covered under the Hazardous Wastes (Management, Handling & Transboundary Movement) Rules, 2008. Sourc e of HW Gene ratio n of HW Catego ry as per
Sched ule Storage
/dispos al
arrange ments Status of Authori zation
--
E Detail of solid wastes (other than hazardous wastes) generation and Source of solid wastes Generation of solid waste Storage/ Disposal arrangeme
its sources. Which environmentally sound measures will be taken for storage and disposal of the same? nts
NIL
F Whether the industry has submitted all the required documents? (details of documents
to be mentioned) Yes, Application Form, C.A Certificate, compliance report and Approved building plan etc.
Recommendations:
It is submitted that earlier the industry was operated under name & style M/s Madhav Stelco Pvt. Ltd. Unit-II and was earlier granted consent to operate under the Water (Prevention & Control of Pollution) Act, 1974 vide no. CTOW/Renew/FGS/2021/15412910 dated 05/04/2021, valid upto 31/12/2030 and under the Air (Prevention & Control of Pollution) Act, 1981 vide no. CTOA/Renewal/FGS/2021/15412910 dated 05/04/2021, valid upto 31/12/2030 for manufacturing of Angle/ Channels / Beam @ 300 TPD with suitable conditions.
Now, the industry has applied under new name and style i.e. M/s Madhav Udyog Private Limited Rolling Division for obtaining fresh consent to operate under the Water (Prevention & Control of Pollution) act, 1974 and the Air (Prevention & Control of Pollution) Act, 1981 with requisite documents through OCMMS for the manufacturing of Angel/Beams/Channels @ 300 TPD with PNG as its fuel.
It is also pertinent to mention here that the industry had already obtained PNG connection from M/s IRM Energy Pvt. Ltd for using the same in its re-heating furnace in place of furnace oil / producer gas. However, the industry had stopped using PNG after trial period because of because of financial non viability. Now, as per the latest directions issued by the Board, the industry has started using only PNG for its re-heating furnace.
Accordingly, the industry has deposited consent fees as mentioned at Sr. no. vii (A) on account of Water consent fee and Air consent fees against the fixed assets of Rs. 1700.00 Lacs as per CA certificate dated 01.03.2026. The consent fee deposited by the industry is now adequate up to 28.02.2031 under the both acts as per Board’s office order dated 29/10/2018 under the green category as the industry is operating on PNG. Accordingly, the industry has also deposited NOC Fees of Rs. 10,800/- for increase in value of fixed assets, which is appropriate.
To verify the contents of application, the industry was visited by Er.Shubham Puri, AEE of this office on 17.04.2026. During visit, it was observed as under:
1. The industry was not in operation due to planned maintenance.
2. The industry has installed 01 no. PNG fired re-heating furnace of capacity 300 TPD. Meter has been installed with the furnace, reading at site 13551105 m3. The industry has maintained the record of the same.
3. The industry has installed rolling mill in its premises for manufacturing of Angles/Channels/Beams.
4. The industry has installed one no. DG set of capacity 200 KVA, which is provided with canopy and stack of adequate height.
5. 01 no submersible has been installed as source of fresh water. Water meter has been installed on it. Reading of the same is 14941 KL during visit and record has been maintained by the industry.
6. The industry has provided system to re-circulate the cooling water.
7. No water is used in the process, so no trade effluent is generated. Domestic effluent is discharged on land for plantation after passing through septic tank.
8. Movement area has been stabilized in the premises of industry.
9. Plantation on one side of boundary wall has been provided. The rep. was advised to enhance the plantation.
Further, the industry is located in the Industrial Zone as per Master Plan of Mandi Gobindgarh. The industry is complying with the conditions of consents granted to it under the Air Act, 1981.
In view of above-mentioned facts, may if approved it is recommended that the industry may be granted fresh consents to operate under the Water (Prevention & Control of Pollution) Act, 1974 and the Air (Prevention & Control of Pollution) Act, 1981 upto up to 31.12.2030 for manufacturing of Angel /Beams/ Channels @ 300 TPD under the green category with suitable conditions and other additional conditions that:
1. The industry shall apply for fresh NOC of the Board, if it changes any of its products/process and also will also apply for varied consent to operate under the Water (Prevention & Control of Pollution) Act 1974 & Air (Prevention & Control of Pollution) Act 1981 in this office.
2. The industry shallobtain necessary statutory permissions/clearances from all other concerned departments.
3. The industry shall not install boiler, furnace without prior approval of the Board.
4. The industry shall make sure no black smoke is generated at any time from the stack of the industry.
5. The industry shall provide proper plantation within one month and shall submit report to this office.