| File Note: |
It is submitted that the results of the effluent as well as emission samples are given below:
Effluent samples:
S. No. Test Parameters Units Results Test Method
1 pH - 6.8 IS 3025 Part-11
2 Total Suspended Solids (TSS) mg/l 12 IS 3025 Part-17
3 Chemical Oxygen Demand (COD) mg/l 196 IS 3025 Part-58
4 Bio-chemical Oxygen Demand (BOD) mg/l 22 IS 3025 Part-44
Oil & Grease mg/l 5.2 -
Stack Emission:
S. No. Point of Sample Collection Test Parameter Units Results Method Reference
1 Port hole on Stack after APCD attached with Dust Extraction Unit 003 Particulate Matter (PM) mg/Nm3 11 IS 11255 (Part 1): 1985,
RA 2019
2 Port hole on Stack after APCD attached with Dust Extraction Unit 003 Particulate Matter (PM) mg/Nm3 45
3 Port hole on Stack after APCD attached with Dust Extraction Unit 003 Particulate Matter (PM) mg/Nm3 28
As per analysis reports, the parameters were found within the permissible limits of the Board.
Submitted, please. |