ApplicationProcessingDetails List

Id Approve Approve Note Clarification Clarification Note Date Created
25866250 false false 1. As mentioned in the reply of clarification, industry has not submitted the details of heating kettles. Clarification:- The Heating Vessel is of 3tone capacity vessel which is used in processing grease. The vessel is connected with thermic fluid storage tank and hot oil pipelines that in turn are inter connected with the thermostat and cooking vessel for all cooking needs to perform consistently at high temperatures with low pressure. The temperature which we require for cooking of grease soap is nominal around 70-90degree. It is further intimated that the industry was issued show cause notice for violation of provisions of the Water Act, 1974 and Air Act, 1981 with an opportunity of personal hearing before the Senior Environmental Engineer, Zonal Office-I, Ludhiana on 03.06.2024, which was attended by Sh. Saravjit Singh, Prop. of the industry in which following decisions were taken (copy attached) :- 1. The industry shall close soakage pit immediately and develop adequate plantation area for discharge of treated domestic effluent. Clarification:- Sir, On last hearing it was informed that the soakage is permanently closed and adequate plantation area for discharge of treated domestic effluent is developed with septic tanks. 2. The industry shall submit within 02 days, the Bank Guarantee of Rs. 1.00 lac, as already imposed during hearing held on 15.05.2024. Clarification:- Sir, For bank guarantee. It was informed us on 27/05/2024 and on 03/06/2024 hearing we have requested some time for 7-10days. It will be submitted as asap. 2. In case, the industry fails to make the compliance, action u/s 33-A of the Water (Prevention & Control of Pollution) Act, 1974 and u/s 31-A of the Air (Prevention & Control of Pollution) Act, 1981 shall be recommended to CEE Ludhiana. Clarification:- Sir, All the compliance for air and water are done. 4. The Environmental Engineer, Regional Office shall verify submission made by industry and submit further recommendations, accordingly. Clarification:- Sir, The Concerned Officer can any time verify the facts made by the industry. In light of above, you are requested to submit the following details within 2 days.:- 1. Details of heating details:- Done 2. Point-wise compliance of the decisions of personal hearing as mentioned above – Replied. 2024-06-07 08:56:49.517
25945603 false false 2024-06-18 12:54:38.741
26016288 false false 2024-06-25 12:52:17.361
26095566 false false 2024-07-01 16:59:23.652
26158542 false false 2024-07-06 20:30:35.278
26158550 false false 2024-07-06 20:32:17.465
26252090 false false 2024-07-16 15:29:58.025
26306082 false false 2024-07-19 16:44:45.524
26364882 false true The application of the industry for obtaining fresh consents under the Water Act, 1974 and varied consent under Air Act, 1981 has been scrutinized and following observations were made: 1. The industry is required submit latest CA certificate showing un-depreciated value of fixed assets as on 30.06.2024 and shall submit consent fees as per the value of fixed assets. 2. The industry shall also deposit NOC regularization fees i.e. 50% of NOC fees. 3. The industry is required submit stack analysis report for its APCD installed on heating furnace. 4. The industry is required submit adequacy and efficacy certificate for its APCD installed on heating furnace. As such you are requested to clarify the aforesaid observations within 02 days, so as to proceed further in the matter. Till then, the application submitted by the industry shall be treated as incomplete. 2024-07-24 16:07:35.466
24978678 false false 2024-02-23 07:30:35.372
Previous1..197647197648197649197650197651197652197653197654197655197656..201531Next